WAGO 852-1112 Скачать руководство пользователя страница 28

28 

Connect Devices 

WAGO-ETHERNET-Zubehör 852 

 

 

852-1112 8-Port 1000BASE-T-Industrial-Eco-Switch 

 

Manual 

 

Version 1.1.0FW/HW-Version 01/01 

Pos: 25 /All e Seri en (Allgemei ne Module)/Ü berschriften/Ebene 1/Geräte anschließ en - Überschrift 1 @ 3\mod_1234172889468_21.docx @ 27460 @ 1 @ 1 

 

Connect Devices 

Pos: 26 /Serie 852 (ETH ERNET-Zubehör)/Anschließ en/Anschluss Spannungsversorgung 852-1112 @  27\mod_1471932636472_21.docx @ 218977 @ 2 @ 1 

 

6.1 

Power Supply 

The industrial ECO switch uses direct-current power supply for 9 … 57 V. 

The primary network link is established via a 2-pin plug-in connection located on 

the top of the industrial ECO switch. 

The female connector (order-no. 2231-102/026-000) is composed of two 

connecting terminals and can be inserted and removed easily by hand to connect 

to the 2-pin plug connector located on the top of the switch. 

1. 

PWR +/- conductors: 

To connect or disconnect the conductors, actuate the spring directly in the 

female connector using a screwdriver or an operating tool and insert or 

remove the conductor. 

2. 

Plug the female connector into the male connector of the switch if it has not 

already been plugged in. 

3. 

Connect a suitable grounding conductor to the grounding lug on the top of 

the industrial ECO switch. 

 

 

 

Important note! 

The ground for the industrial ECO switch prevents electromagnetic interference 

from electromagnetic radiation.  

Observe the corresponding standards for EMC-compatible installations as well. 

4. 

Check whether the power LED on the top of the device lights up when 

power is supplied to the device. If not, check to ensure that the power cable 

is plugged in correctly and fits securely. 

Pos: 27 /D okumentation allgemei n/Glieder ungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810  @   @  1 

 

 

 

Содержание 852-1112

Страница 1: ...GO ETHERNET Zubeh r 852 Manual 852 1112 8 Port 1000BASE T Industrial Eco Switch Mounting Installation and Handling Version 1 1 0 FW HW Version 01 01 Pos 3 Alle Serien Allgemeine M odul e Rechtliches A...

Страница 2: ...8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully e...

Страница 3: ...ions for Operating the Industrial Switches 10 2 2 Safety Advice Precautions 11 2 3 Special Use Conditions for ETHERNET Devices 13 3 General 14 3 1 Package Contents 14 3 2 Industrial ETHERNET Technolog...

Страница 4: ...Manual Version 1 1 0FW HW Version 01 01 5 1 Installation site 26 5 2 Installation on a Carrier Rail 26 5 3 Removal from Carrier Rail 27 6 Connect Devices 28 6 1 Power Supply 28 7 Appendix 29 7 1 RJ 45...

Страница 5: ...entati on 852 xxxx 16 mod_1378458208696_21 docx 130868 1 This documentation is only applicable to WAGO ETHERNET accessory products 8 Port 1000BASE T Industrial Eco Switch 852 1112 Pos 11 All e Seri en...

Страница 6: ...s injury Pos 12 5 4 All e Serien Allgemei ne Module Sicherheits und sonstige Hi nweise Vorsicht Vorsicht _War nung vor Personensch den allgemein_ Erl uterung 13 mod_1343310028762_21 docx 101038 1 Pers...

Страница 7: ...dustrial Eco Switch Manual Version 1 1 0FW HW Version 01 01 Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet Pos 12 6 Dokume...

Страница 8: ...184814 2 1 1 5 Font Conventions Pos 12 10 Alle Serien Allgemeine M odul e Rechtliches Allgemeines Schriftkonventi onen 3 mod_1221059521437_21 docx 21714 1 Table 2 Font Conventions Font Type Indicates...

Страница 9: ...q ualifi kati on 852 xxxx berschrift 3 und Inhal t 3 mod_1222346340968_21 docx 22264 3 1 2 1 2 Personnel Qualification All sequences implemented on Series 852 devices may only be carried out by electr...

Страница 10: ...up maintenance and repair please observe the accident prevention regulations of your machine e g BGV A 3 Electrical Installations and Equipment Emergency stop functions and equipment must not be deact...

Страница 11: ...eachten 6 mod_1260180657000_21 docx 46735 1 Pos 15 12 4 Alle Serien Allgemeine M odul e Sicherheits und sonstige Hinweise Gefahr Gefahr Auf nor mgerechten Anschl uss achten 6 mod_1260180753479_21 docx...

Страница 12: ...en der D aten und Versorgungsleitungen vermeiden 6 mod_1260184045744_21 docx 46767 1 Do not reverse the polarity of connection lines Avoid reverse polarity of data and power supply lines as this may...

Страница 13: ...commends putting control components and control networks behind a firewall Limit physical and electronic access to all automation components to authorized personnel only Change the default passwords b...

Страница 14: ...ond the limits of ETHERNET technology is the development of switching technology A switch bridge ETHERNET packets at the MAC address level of the ETHERNET protocol transmitting among connected ETHERNE...

Страница 15: ...ackages or messages are relayed via subsections from one network node to the next where they a buffered for a short time Here they are checked for correctness and validity and then discarded or relaye...

Страница 16: ...e 852 1112 is an industrial ETHERNET switch with 8 10 100 1000Base T ports with auto negotiation and auto MDI MDI X detection at every port Using the industrial ECO switch s 8 ports several segments c...

Страница 17: ...ten 852 1112 27 mod_1471868059183_21 docx 218769 33 1 4 1 1 Front View Figure 1 Front View of the Industrial ECO Switch Table 3 Legend for Figure Front View of the Industrial ECO Switch Pos Descrip ti...

Страница 18: ...re 2 Top View of the Industrial ECO Switch Table 4 Legend for Figure Top View of the Industrial ECO Switch Pos Descrip tion Meaning Details see Section 1 Grounding screw 2 Terminal block male connecto...

Страница 19: ...an easily be connected to the 2 pole male connector located on the top of the industrial ECO switch The male connector shows the following pin assignment Figure 3 Power Supply PWR Port Table 5 Legend...

Страница 20: ...twork Connections No Descrip tion Meaning Details see Section 1 Connection 8 x RJ 45 10 100 1000BASE T ports Device Description 10 100 1000BASE T ports 4 2 2 1 10 100 1000Base T The 10 100 1000Base T...

Страница 21: ...bung Anzeigeelemente LED Anzeigen 852 1112 27 mod_1471870736281_21 docx 218891 33 1 The industrial switch is equipped device LEDs and port LEDs You can see the status of the industrial switch at a qui...

Страница 22: ...ion 1000 10 100 1000BASE T Ports LED 1 LED for each port Green Port in operation at 1000 Mbit s OFF Connection in operation at less than 1000 Mbit s LNK ACT LNK ACT LED 1 LED for each port Green Light...

Страница 23: ...kleber 852 1xx2 27 mod_1471597008498_21 docx 218591 23 1 4 4 Label 4 4 1 Hardware and Software Version There is a label with the serial no SN on the back of the industrial switch Figure 7 Label Exampl...

Страница 24: ...y Table 11 Technical Data Power Supply Supply voltage 9 57 VDC Power consumption max 6 W 4 5 3 Communication Table 12 Technical Data Communication Ports 8 x 10 100 1000BASE T RJ 45 Standards IEEE 802...

Страница 25: ...lassungen CE Konfor mit tskennzeichnung 3 mod_1224494777421_21 docx 24276 1 Conformity Marking Pos 21 22 D okumentati on allgemei n Gli ederungsel emente Leerzeile 3 mod_1224662755687_0 docx 24460 1 P...

Страница 26: ...wing rules Install the industrial ECO switch at an appropriate place See section Device Description Technical Data for the acceptable temperature and humidity operating ranges Pos 23 3 Serie 852 ETH E...

Страница 27: ...rsion 01 01 5 3 Removal from Carrier Rail To remove the device from the carrier rail press down on the industrial ECO switch and pull it out of the carrier rail Figure 9 Removing the Device from the C...

Страница 28: ...connect to the 2 pin plug connector located on the top of the switch 1 PWR conductors To connect or disconnect the conductors actuate the spring directly in the female connector using a screwdriver or...

Страница 29: ...88 2 1 7 1 RJ 45 Cable Always use category 5e cables to connect your network devices The pin assignment is given below Table 14 RJ 45 Cable Contact Description Pair Color acc EIA TIA 568B 4 wire 8 wir...

Страница 30: ...21080 1 List of Figures Figure 1 Front View of the Industrial ECO Switch 17 Figure 2 Top View of the Industrial ECO Switch 18 Figure 3 Power Supply PWR Port 19 Figure 4 Network Connections 20 Figure 5...

Страница 31: ...of the Industrial ECO Switch 17 Table 4 Legend for Figure Top View of the Industrial ECO Switch 18 Table 5 Legend fort Figure Power Supply PWR Port 19 Table 6 Legend fort the Figure Network Connection...

Страница 32: ...te 2015 9 mod_1285229376516_21 docx 64944 1 WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Intern...

Отзывы: