852-111/000-001
Connection
Product manual | Version: 1.0.1
23
Industrial-Eco-Switch
8
Connection
8.1 Grounding
Grounding is through the grounding screw or the female connector on the top of the prod-
uct.
The switch must be grounded. To do this, connect the grounding screw or the corre-
sponding contact on the female connector to the ground potential. Do not operate the
switch without an appropriate protective ground conductor installed.
8.2 Connecting the Supply Voltage
The switch uses direct current power supply of 12 … 48 VDC.
The primary network link is established via a 2-pin plug-in connection located on the top
of the industrial eco switch.
The female connector (Item No. 2231-103/026-000) is composed of three connecting ter-
minals and can be inserted and removed easily by hand to connect to the 3-pin plug con-
nector located on the top of the switch.
The power supply for the switch automatically adjusts to the local power source and can
also be switched on if no or not all patch cables are connected.
1. Connect a suitable grounding conductor to the grounding screw or appropriate con-
tact on the female connector on the top of the switch.
Note
Ground for the switch
The ground for the switch prevents electromagnetic interference from electromagnetic ra-
diation.
Observe the corresponding norms for EMC-compatible installations as well.
2. Plug the female connector into the male connector of the switch if it has not already
been plugged in. Check the tight fit of the multipoint connector by gently shaking it.
3. PWR +/-:
To connect or disconnect the conductors, press the push-button of the female con-
nector using a screwdriver or an operating tool and insert or remove the conductor.
4. Check whether the power LED “PWR” on the top of the device lights up when power
is supplied to the product. If not, check that the power cable is correctly and securely
plugged in.
8.3 Connect 10/100BASE-TX Ports
The 10/100BASE-TX ports (RJ-45 Ethernet ports) of the industrial eco switch support
both auto-sensing and auto-negotiation.
1. Connect one end of the patch cable to the available RJ-45 port on the industrial eco
switch and the other end to the port on the selected network device.