2.2
Safety Advice (Precautions)
Pos: 16.13 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Gefahr/Gefahr: El ektrische Spannung @ 8\mod_1278307980373_21.docx @ 58901 @ @ 1
Electric voltage!
Operate the 767 Series components exclusively with 24 VDC PELV (Protective
Extra Low Voltage) or SELV (Safety Extra Low Voltage) voltage sources. Failure
to comply may result in electric shock.
Pos: 16.14 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Vorsicht/Vorsicht: Heiß e Anschlussbuchsen @ 8\mod_1278308217203_21.docx @ 58913 @ @ 1
Hot connection sockets!
Even when taking into account derating, high surface temperatures on the metallic
connection sockets and on the enclosure can arise during operation. If the 767
Series component has been in operation, allow it to cool off before moving it.
Pos: 16.15 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Achtung/Achtung: Höchste Strombel astbar keit M 23 @ 8\mod_1278308039077_21.docx @ 58904 @ @ 1
The highest current carrying capacity of the M23 supply contacts is 24A!
The supply lines of the M23 supply input shall only be charged with a maximum
of 8A for U
LS
and 16A for U
A
. If the maximum current carrying capacity is
exceeded, both the connectors and components will be damaged. The module
supply input is not automatically monitored for overload.
Pos: 16.16 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Achtung/Achtung: Höchste Strombel astbar keit M 12 @ 8\mod_1278308104531_21.docx @ 58907 @ @ 1
The highest current carrying capacity of the M12 supply contacts is 4A!
Supply lines U
LS
and U
A
of the M12 supply outputs shall each be charged with a
maximum of 4A. If the maximum current carrying capacity is exceeded, both the
connectors and components will be damaged. The module supply output is not
automatically monitored for overload.
Pos: 16.17 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Achtung/Achtung: Offene Anschl üsse @ 8\mod_1278308159953_21.docx @ 58910 @ @ 1
Exposed connections!
If connections have not been closed with protective caps, liquid or dirt can
penetrate the components of the 767 Series module and ruin it. Therefore, close
all unnecessary connections with protective caps, which must be ordered
separately, in order to maintain the IP67 degree of protection. (See "Accessories"
section of the fieldbus coupler/controller manual.)
Pos: 16.18 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/I/O-Modul /Sicher hei tshi nweise 767- xxxx_2 @ 7\mod_1267623532771_21.docx @ 51669 @ @ 1
•
Disconnect the power supply from the system on which you wish to mount
the 767 Series device.
•
Observe the appropriate accident prevention regulations for your system
during assembly, start-up, maintenance, and repairs. For example, BGV A3,