background image

4  

  

 

Important Comments 

 

 

 Legal 

Principles 

 

 

  

WAGO-I/O-SYSTEM 

750 

  

I/O 

Modules 

1 Important Comments 

To ensure fast installation and start-up of the units described in this manual, 
we strongly recommend that the following information and explanations are 
carefully read and abided by. 

1.1 Legal Principles 

1.1.1 Copyright 

This manual is copyrighted, together with all figures and illustrations 
contained therein. Any use of this manual which infringes the copyright 
provisions stipulated herein, is not permitted. Reproduction, translation and 
electronic and photo-technical archiving and amendments require the written 
consent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will 
entail the right of claims for damages. 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform 
modifications allowed by technical progress. In case of grant of a patent or 
legal protection of utility patents all rights are reserved by WAGO 
Kontakttechnik GmbH & Co. KG. Products of other manufacturers are always 
named without referring to patent rights. The existence of such rights can 
therefore not be ruled out. 

1.1.2 Personnel 

Qualification 

The use of the product detailed in this manual is exclusively geared to 
specialists having qualifications in PLC programming, electrical specialists or 
persons instructed by electrical specialists who are also familiar with the valid 
standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability 
resulting from improper action and damage to WAGO products and third party 
products due to non-observance of the information contained in this manual. 

1.1.3 Intended 

Use 

For each individual application, the components supplied are to work with a 
dedicated hardware and software configuration. Modifications are only 
permitted within the framework of the possibilities documented in the 
manuals. All other changes to the hardware and/or software and the non-
conforming use of the components entail the exclusion of liability on part of 
WAGO Kontakttechnik GmbH & Co. KG. 

Please direct any requirements pertaining to a modified and/or new hardware 
or software configuration directly to WAGO Kontakttechnik GmbH & Co. 
KG. 

Содержание 750-559

Страница 1: ...Fieldbus Independent I O Modules 4 AO DC 0 10 V 750 559 xxx xxx Manual Version 1 0 6 ...

Страница 2: ...0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be fully ex cluded we would appreciate any information or ideas at any time E Mail documentation wago com We wish to point out that the software and hardware terms as well as the trademarks of companie...

Страница 3: ...ntended Use 4 1 2 Symbols 5 1 3 Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Analog Output Modules 7 2 1 1 750 559 xxx xxx 4 AO DC 0 10 V 7 2 1 1 1 Variations 7 2 1 1 2 View 7 2 1 1 3 Description 8 2 1 1 4 Display Elements 9 2 1 1 5 Schematic Diagram 9 2 1 1 6 Technical Data 10 2 1 1 7 Process Image 11 2 1 1 7 1 Standard Format 11 ...

Страница 4: ...nufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual is exclusively geared to specialists having qualifications in PLC programming electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards WAG...

Страница 5: ...SD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient use of the device and software optimization More information References on additional literature manuals data sheets and internet pages 1 3 Number Notation Number Code Example Note Decimal 100 normal notati...

Страница 6: ...D information is to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assembled in housings cabinets or in electrical operation rooms Access must only be given via a key or tool to authorized qualified personnel The relevant valid and applicable standards and guidelines con...

Страница 7: ...Description 750 559 4 AO DC 0 10 V 4 Channel Analog Output Module 0 10 V 750 559 025 000 4 AO DC 0 10 V T 4 Channel Analog Output Module 0 10 V extended temperature range from 20 C to 60 C 2 1 1 2 View A1 A2 13 14 C D B A 750 559 M M A3 A4 M M B AO 2 Power jumper contacts Datacontacts Common ground Function AO 1 Common ground Common ground AO 4 AO 3 Common ground Error Fig 2 1 1 1 4 Channel Analog...

Страница 8: ...ill show if there are any overload or a short circuit to ground in either channel Any configuration of the output modules is possible when designing the fieldbus node Grouping of module types is not necessary The system supply is used for the power supply of the module The field side supply voltage of 0 V and 24 V to downstream I O modules is derived from adjacent I O modules or from a supply modu...

Страница 9: ...on Operational readiness and trouble free internal data bus communication off No Error 13 14 C D B A A B Fig 2 1 1 2 Display elements g055702x B red Error on Overload or short circuit to ground in one of the output channels 2 1 1 5 Schematic Diagram 750 559 1 2 3 4 5 6 7 8 AO 1 AO 2 Common ground 24V AO 3 0V Common ground AO 4 AO Logic Function 270 pF 10 nF Common ground Error Fig 2 1 1 3 4 Channe...

Страница 10: ...ns W x H x L from upper edge of 35 DIN rail 12 mm x 64 mm x 100 mm Weight ca 55 g Standards and Regulations cf Chapter 2 2 of the Coupler Controller Manual EMC Immunity to interference CE acc to EN 50082 2 96 EMC Emission of interference CE acc to EN 50081 1 93 EMC Immunity to interference Ship building acc to Germanischer Lloyd 01 EMC Emission of interference Ship building acc to Germanischer Llo...

Страница 11: ...B14 The three least significant bits B0 B2 are not parsed Some fieldbus systems can process the status information using by means of a status byte As the returned status byte of this output module is always zero it will not be parsed 2 1 1 7 1 Standard Format For the standard module 750 559 the numerical values ranging from 0x0000 to 0x7FFF are scaled on the output current ranging from 0 V to 10 V...

Страница 12: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastraße 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com ...