1 Important Comments 

To ensure fast installation and start-up of the units described in this manual, 
we strongly recommend that the following information and explanations are 
carefully read and abided by. 

1.1 Legal Principles 

1.1.1 Copyright 

This manual is copyrighted, together with all figures and illustrations con-
tained therein. Any use of this manual which infringes the copyright provi-
sions stipulated herein, is not permitted. Reproduction, translation and elec-
tronic and photo-technical archiving and amendments require the written con-
sent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail 
the right of claims for damages. 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modi-
fications allowed by technical progress. In case of grant of a patent or legal 
protection of utility patents all rights are reserved by WAGO Kontakttechnik 
GmbH & Co. KG. Products of other manufacturers are always named without 
referring to patent rights. The existence of such rights can therefore not be 
ruled out. 

1.1.2 Personnel Qualification 

The use of the product detailed in this manual is exclusively geared to special-
ists having qualifications in PLC programming, electrical specialists or per-
sons instructed by electrical specialists who are also familiar with the valid 
standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability re-
sulting from improper action and damage to WAGO products and third party 
products due to non-observance of the information contained in this manual. 

1.1.3 Intended Use 

For each individual application, the components supplied are to work with a 
dedicated hardware and software configuration. Modifications are only per-
mitted within the framework of the possibilities documented in the manuals. 
All other changes to the hardware and/or software and the non-conforming use 
of the components entail the exclusion of liability on part of WAGO Kon-
takttechnik GmbH & Co. KG. 

Please direct any requirements pertaining to a modified and/or new hardware 
or software configuration directly to WAGO Kontakttechnik GmbH & Co. 
KG. 

Содержание 750-523

Страница 1: ...Fieldbus Independent I O Modules 1 DO AC 230 V 16 A Relay 1a Pot free 750 523 Manual Version 1 0 5...

Страница 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Страница 3: ...er Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Digital Output Modules 7 2 1 1 750 523 1 DO AC 230 V 16 A Relay 1a Pot free 7 2 1 1 1 View 7 2 1 1 2 Description 7 2 1 1 3 Display Elem...

Страница 4: ...are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual is exclusiv...

Страница 5: ...ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient use...

Страница 6: ...s to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assembled in housin...

Страница 7: ...2 Description A connected actuator or load is switched via the relay output module The 24 V supply is derived from the power jumper contacts to trigger the re lays The module has one output channel a...

Страница 8: ...stem requiring a 24 V power supply fed in via the internal power jumper contacts of an adjacent supply module In this operating mode manual status transitions which may occur via the red manual operat...

Страница 9: ...0 476 2 DI DC 10 V up to version number 3005 The output module has 24 V and 0 V built in power jumper contacts The 24 V power supply is used to trigger the relays The module is powered using an adjace...

Страница 10: ...ay Elements g052302x LED Channel Designation State Function off Operating mode automatic yellow flashing 1 Status manual operation on Operating mode manually operated LED Channel Designation State Fun...

Страница 11: ...A Contact material AgSnO2 Mechanical life 106 switching operations Isolation 1 5 kVeff System Field 2 5 kV rated surge voltage overvoltage category III Internal bit width 2 Bit In Manual status 2 Bit...

Страница 12: ...d 1 000 W 2 000 W Mercury arc sodium discharge lamp parallel compensated 1 000 W 70 F 2 000 W 140 F Dulux lamp not compensated 800 W 1 600 W Dulux lamp parallel compensated 560 W 70 F 1 100 W 140 F Mo...

Страница 13: ...Value Graph of the Relay WAGO I O SYSTEM 750 I O Modules 2 1 1 7 Load Limiting Value Graph of the Relay 100 0 1 1 10 10 20 30 50 200 300 0 5 5 16 20 Direct Current A Direct Voltage V Fig 2 1 1 5 Direc...

Страница 14: ...fective Attenuation Advantages Disadvantages Diode UD Load g051211e long yes UD no Advantages easy implementation cost effective reliable uncritical dimensioning low induction voltage Disadvantages at...

Страница 15: ...Digital Output Modules 15 Contact Protective Circuit for Relay Modules WAGO I O SYSTEM 750 I O Modules...

Страница 16: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...