Operating manual Pneumatic double diaphragm pump ZIP52 (PF Eco) Finishing
6 Assembly and Commissioning
Order number 2332848 | Edition 08/2020
31
B_06945
1
2
3
4
5
6
7
Grounding scheme (example)
Pos
Part / workstation
Cable cross section
1
Conveyor
16 mm²; AWG6
2
Work piece
--
3
R
max
< 1 M
Ω
--
4
Spraying stand
Alternative: Spray booth
16 mm²; AWG6
5
Floor, static dissipative
--
6
Product tank
6 mm²; AWG10
7
Pump
4 mm²; AWG12
Info
Safe operation of the pump is only guaranteed with a grounding connection. Connect all
grounding cables using a short and direct route.
B_04049
1. Remove the crimp connection delivered with the pump.
2. Crimp the grounding cable on the connection and screw it back onto the pump’s foot.
3. Ground the product tank to an on-site grounding connection.