10
40 ccm - 300 ccm
.
SERVICE MANUAL
EDITION 01/2012
PART NO. DOC367866
2.4.1
CORRECT USE
2.4.2
EXPLOSION PROTECTION IDENTIFICATION
2.4.3
IDENTIFICATION X
2.4
USE IN AN EXPLOSION HAZARD AREA
4HEUNITISSUITABLEFORWORKINGLIQUIDMATERIALSINACCORDANCEWITHTHECLASSIlCATIONINTO
EXPLOSIONCLASSES
As defined in the Directive 94/9/EC (ATEX 95), the unit is suitable for use in areas where
there is an explosion hazard.
II 2G IIB c T3 X
CE: Communautés
Européennes
Ex: Symbol for explosion protection
II:
Unit
class
II
2: Category 2 (Zone 1)
G: Ex-atmosphere gas
IIB: Explosion
group
c: Constructional
security
T3: Temperature class: maximum surface temperature < 200 °C; 392 °F.
X: Special Notes (see chapter 2.4.3)
Maximum surface temperature
The maximum surface temperature of the piston pump can be reached if it runs dry.
Ensure that the piston pump is filled with sufficient working or cleaning medium.
Ensure that the separating fluid container is filled with sufficient separating fluid.
Ignition temperature of the coating material
Ensure that the ignition temperature of the coating material is above the maximum
surface temperature.
Ambient temperature
The permissible ambient temperature is +5 °C to +60 °C; +41 °C to 140 °F
Medium supporting atomizing
To atomize the material, use only weakly oxidizing gases, e.g. air.
Mechanical sparks can form if the unit comes into contact with metal
In an explosive atmosphere:
Do not knock or push the unit against steel or rusty iron.
Do not drop the unit.
Use only tools that are made of a permitted material.
Содержание Wildcat 18-40
Страница 2: ......
Страница 73: ...73 40 ccm 300 ccm SERVICE MANUAL EDITION 01 2012 PART NO DOC367866...
Страница 79: ...79 40 ccm 300 ccm SERVICE MANUAL EDITION 01 2012 PART NO DOC367866...
Страница 99: ......