51
TwinControl
.
OPERATING MANUAL
EDITION 04/2010
PART NO. DOC393831
8. Repeat the calibration in order to check it.
Large deviations may be due to the following
error causes
:
- There is air in the lines -> Fill lines with material and check suction system.
- High proportion of air bubbles in the material in the measuring cup -> Determine
material weight with scale and calculate the volume based on the density.
9. Calibrate the B component in the same way as the A component.
10. The K-factor can be entered directly for the fl ushing pump. The value corresponds to
cm
3
per double stroke.
11. Flush the system.
DANGER
Exploding gas/ air mixture!
Danger to life from flying parts and burns
Never spray into a closed container.
Earth the container.
SIHI_0008_GB
6.7
FLUSH SYSTEM
Flushing must always be carried out
- before prolonged work interruptions
- at the end of work
- before expiry of the application life
- before a material change.
➞
If a high-pressure gun is used, remove the spray nozzle before fl ushing.
Note
: Before the spray nozzle is removed, the pressure (see section. 6.4) has to be
released.
➞
Wear protective eye wear.
➞
Set the fl ushing agent pressure as low as possible for fl ushing.
Procedure:
1. Press the Stop button.
2. Press the Flush button. Open gun carefully and spray into an earthed container. Flush
until clean fl ushing agent emerges. Repeat fl ushing cycle if necessary or adjust fl ushing
quantity in fl ushing program. Adjust fl ushing pressure at the fl ushing pump so that the
desired fl ushing effect is achieved.
Содержание TwinControl 18-40 ABS
Страница 2: ......
Страница 67: ...67 TwinControl OPERATING MANUAL EDITION 04 2010 PART NO DOC393831...
Страница 75: ...75 TwinControl OPERATING MANUAL EDITION 04 2010 PART NO DOC393831...
Страница 79: ......