31
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC 2366672
7.3
WORKING
1. Secure gun and place nozzle in the gun.
2. Slowly open the ball valve.
3. Set the required working pressure on the pressure regulator.
4. Optimize the spraying results as laid down in the gun instructions.
5. Start work process.
7.4
PRESSURE RELIEF/WORK INTERRUPTION
7.4.1
PRESSURE RELIEF/WORK INTERRUPTION
The pressure must always be relieved when:
- The spraying tasks are fi nished.
- Servicing the system.
- Carrying out cleaning tasks on the system.
- Moving the system to another location.
- Something needs to be checked on the system.
- The nozzle is removed from the gun.
Observe general safety instructions in Chapter 4.
Process for relieving pressure
1.
Close gun.
2.
Close ball valve.
3.
Vent the pump.
4.
Release the system by opening the gun.
5.
Close and secure gun.
If the system has been used with 2-component materials:
Hardened product in the spraying system when 2-component product is processed!
Destruction of pump and injection system.
Follow the manufacturer‘s processing rules, particularly regarding the pot life.
Flush thoroughly before the end of the pot life.
The pot life is decreased by warmth.
NOTICE