30
ProSpray 27 • 31
g
Description of unit
Starting operation
3.5 Technical data
ProSpray 27
ProSpray 31
Voltage:
230 V AC, 50 Hz
Max. current consumption:
7.5 A
8.7 A
Fuses:
16 A time-lag
Unit connecting line:
3 x 1.5 mm
2
– 6 m
Acceptance capacity:
1725 Watts
2000 Watts
Max. operating pressure:
230 bar (23 MPa)
Volume flow at 120 bar
(12 MPa) with water:
2.7 l/min
3.1 l/min
Max. tip size:
0.027 inch
0.031 inch
– 0.69 mm
– 0.79 mm
Max. temperature of the
coating material:
43°C
Max. viscosity:
30.000 mPa·s
Filter insert
(standard outfitting):
mesh 60
Weight:
39 kg
Max. tire pressure:
2 bar (0.2 MPa)
Special high-pressure hose:
DN 6 mm, 15 m connecting
thread M 16 x 1.5
Dimensions (L x W x H):
655 x 825 x 640 mm
Max. sound pressure level:
79 dB (A) *
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 120 bar (12 MPa) operating pressure,
reverberant floor.
3.6 Transportation
Pushing or pulling the unit
Pull out the handle (Fig. 3, Item 1) until it will come no
further. Insert the handle – push the buttons (2) on the
spars, and then push in the handle.
1
2
2
5
3
1
2
4
3.7 Transportation in vehicle
Roll the high-pressure hose over the suspension device
at the handle.
Secure the unit with a suitable fastening.
4. Starting operation
4.1 High-pressure hose, spray gun and
separating oil
1. Screw the manometer combination (2) at the coating
material outlet (Fig. 4, Item 1).
2. Screw the transition socket (3) to the manometer
combination.
3. Screw the high-pressure hose (4) to the manometer
combination.
4. Screw the spray gun (5) with the selected tip onto the
high-pressure hose.
5. Tighten the union nuts at the high-pressure hoses
firmly so that coating material does not leak.