45
ProfiTech M
OPERATING MANUAL
VERSION 07/2014
ORDER NUMBER DOC 2335144
X20 terminal block for powder center signal including EMERGENCY STOP
Function
Signal
Terminal strip
Clamps
Contact /Signal type
EMERGENCY STOP from
Powder Center
Channel 1
X20
1 and 2
Potential-free NCC
EMERGENCY STOP from
Powder Center
Channel 2
X20
3 and 4
Potential-free NCC
EMERGENCY STOP
transmission to PC
Channel 1
X20
5 and 6
Potential-free NOC
EMERGENCY STOP
transmission to PC
Channel 2
X20
7 and 8
Potential-free NOC
Outgoing air OK for Powder
Center
Contact
X20
9 and 10
Potential-free NOC
Auxiliary voltage for inputs
+24 VDC
X20
11
+24 VDC from I/O Module
Powder center OK
Digital IN
X20
12
Digital input 24 VDC/3.3 mA
Request PC cleaning
Digital IN
X20
13
Digital input 24 VDC/3.3 mA
Start PC inside cleaning
Digital IN
X20
14
Digital input 24 VDC/3.3 mA
Cleaning ready at PC
Digital OUT
X20
15
Digital output 24 VDC/100 mA
Cleaning preparation PC
Digital OUT
X20
16
Digital output 24 VDC/100 mA
GND for inputs and outputs
GND
X20
17
GND
X21 terminal block for booth control cabinet
Function
Signal
Terminal strip
Clamps
Contact /Signal type
Fire alarm
Channel 1
X21
1 and 2
Potential-free NCC
Fire alarm
Channel 2
X21
3 and 4
Potential-free NCC
EMERGENCY STOP
transmission to booth
control cabinet
Channel 1
X21
5 and 6
Potential-free NOC
EMERGENCY STOP
transmission to booth
control cabinet
Channel 2
X21
7 and 8
Potential-free NOC
Outgoing air OK for EPG S2
Contact
X21
9 and 10
Potential-free NOC
Outgoing air OK for Powder
Center
Contact
X21
11 and 12
Potential-free NOC
Ventilator 1 START/STOP
Digital OUT
X21
13
Digital output 24 VDC/100 mA
Ventilator 2 (20 Hz Eco)
Digital OUT
X21
14
Digital output 24 VDC/100 mA
Ventilator 3 (40 Hz normal)
Digital OUT
X21
15
Digital output 24 VDC/100 mA
Booth light ON/OFF
Digital OUT
X21
16
Digital output 24 VDC/100 mA
Booth cleaning ON/OFF
Digital OUT
X21
17
Digital output 24 VDC/100 mA
Ventilator is running
Digital IN
X21
18
Digital input 24 VDC/3.3 mA
Outgoing air OK
24 VDC Signal
Digital IN
X21
19
Digital input 24 VDC/3.3 mA
GND for inputs and outputs
GND
X21
20
GND
Содержание ProfiTech M
Страница 2: ......
Страница 104: ...104 ProfiTech M OPERATING MANUAL VERSION 07 2014 ORDER NUMBER DOC 2335144...
Страница 105: ...105 ProfiTech M OPERATING MANUAL VERSION 07 2014 ORDER NUMBER DOC 2335144...
Страница 107: ......
Страница 108: ...CERTI F I E D Order No 2335144 Germany Phone Fax E mail Switzerland Phone Fax E mail...