Spray lance without automatic control
• Open material tap (3, fig. 16).
• Turn on device with remote control switch (1, fig. 16).
• Coating material will be pumped into the mortar hose.
• Pump synthetic resin dispersion or cellulose paste from the
mortar hose into a bucket.
• As soon as coating material starts coming out of the spray
lance – turn off device using remote control and close mate-
rial tap on the spray lance.
• Hold spray lance over the receptacle.
• Open material tap (3, fig. 15 and 16) and turn on device us
-
ing remote control.
• Set the feed rate regulator (3, fig. 3, page 31) to the required
feed rate.
• Turn off device using remote control and close material tap
(3, fig. 15 and 16).
• Fasten mortar hose using hose holder to the frame (each
connecting hose separately).
Starting the spraying procedure
• Open air tap (2, fig. 16 and 17) and material tap (3, fig. 15
and 16) on the spray lance.
Spray lance without automatic control
Turn device on using remote control switch (1, fig. 16).
end of the spraying procedure
Spray lance with automatic control
• Turn switching sleeve (1, fig. 15) 90° clockwise as far as it will
go.
• Wait 3–5 seconds.
• Close material tap (3, fig. 15).
Spray lance without automatic control
• Press remote control switch (1, fig. 16) on mortarhose.
• Wait 3–5 seconds.
• Close material tap (3, fig. 16).
Spray lance with automatic control (fig. 15)
Spray lance without automatic control (fig. 16)
8
GeNeRAl ReQuIReMeNtS FOR
APPlICAtION
teCHNOlOGy
Spraying technique
Guide the spray lance at a uniform distance of 30 – 60 cm from
the object when spraying. If you do not do this, you will not
achieve a regular spray pattern. The spray pattern is depend-
ent upon the type of material, material consistency, tip size,
do not kink the mortar hose!
Protect it against damage e.g., resulting
from it being run over or from sharp ob-
jects.
• Close air tap (2, fig. 15).
Noncompliance with the above instruc-
tions will result in additional wear of the
material tap.
Noncompliance with the above instruc-
tions will result in additional wear of the
material tap.
• Close air tap (2, fig. 16).
general requIrements for applIcatIon technology
3
2
1
2
1
3
Spray lance without automatic control
• When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose – turn off device with
remote control switch (1, fig. 16).
• Close material tap (3, fig. 16).
• Check viscosity of the coating material.
• Fill coating material into the receptacle. With mineral coat
-
ing materials only fill the receptacle to half full.
Spray lance with automatic control
• Open material tap (3, fig. 15).
• The coating material will be pumped into the mortar hose.