8.5.2 FITTING THE ROUND JET NOZZLE
Procedure:
1. Before inserting the electrode holder, the spring contact of the
gun body and contact surface of the electrode holder should
be checked.
2.
P_01678
3.
4.
5.
6.
The spring contact must be clean and smooth-running, the
gun body must also be clean and free of powder deposits.
2. Attach deflector cone sleeve onto electrode holder.
3. Insert electrode holder into gun housing.
4. Slide union nut onto gun housing.
5. Screw union nut onto gun housing (hand-tight).
6. Slide deflector cone over deflector cone sleeve.