13
PEM-C4-Ergo
.
OPERATING MANUAL
VERSION 02/2009
ORDER NUMBER DOC2305054
Dimensions:
Length/width/height
see chapter 4.3.1
Weight
504 g; 1.11 lbs
Electrical:
Input voltage
max. 22 Vpp
Input current
max. 0.9 A
Frequency
19-30 kHz
Output voltage
max. 100 kV DC
max. Corona current
120 µA
Polarity
negative
Design
as per EN 50050
Protection class
IP 54
Pneumatic:
Compressed air input pressure
(atomizing air quantity)
max. 3 bar; 0.3 MPa, 43.51 psi
Powder output quantity
max. 450 g/min; max. 0.99 lbs/min.
Operating temperature range
5-45°C; 41-113°F
4.3
TECHNICAL DATA
SIHI_05034_ENG
WARNING
Outgoing air containing oil!
Risk of poisoning if inhaled
Provide water-free and oil-free compressed air (quality standard
3.5.2 as per ISO 8573.1) 3.5.2 = 5 μm / +7°C; 44.6°F / 5mg/m³.
Ambient conditions:
If low temperature powders are used, the ambient temperature may have to be lower than
30°C; 86°F.
Volume measures:
For volumes, specified in Nm³ (standard cubic meters). One cubic meter of a gas at 0°C; 32°F
and 1.013 bar is called norm cubic meter. 1 Nm³/h = 35.3ft³/h; 1 bar = 14.504 psi.