7
FAILURE CORRECTION
If HERITAGE should fail to function despite observance of all instructions,
please proceed as described in the following steps :
1)
It may occur that your HERITAGE is ready for operation but it is covered by
another source of light. In this case, relocate the solar station.
2)
Ensure that your HERITAGE does not stand in the shade during the day.
3)
Check the rechargeable battery for corrosion.
REMOVING / CHANGING THE RECHARGEABLE
BATTERY
• Take off the four fastening screws on the upper part of the lamp
c
.
• Unscrew the luminous elements (two Phillips head screws)
d
.
• Take off the two fastening screws on the protective cover and remove the
protective cover
e
.
• Remove the rechargeable battery to re-load it and/or exchange it
f
.
Re-assembly is accordingly conducted in the reverse order
ATTENTION!
Use Original Wagner rechargeable batteries only.
When exchanging the rechargeable battery, ensure that none of the
connections or wires are damaged.
Winterrise
We recommend storing your HERITAGE in winter at temperatures below 0°C
in a frost-free location and re-erecting it in spring. The rechargeable battery
can be loaded with a commercial net charger.
Special Accessories
Rechargeable battery
Art. No.
1016701