52
GA 5000EAC
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
7.3.7
CHANGING FROM AIRCOAT ROUND JET TO AIRCOAT FLAT JET
Flush spray gun
1. Switch off control unit.
2. Relieve pressure Chapter 7.3.3.
3. Connect the system to the fl ushing agent supply.
4. Set product pressure. Close air pressure regulator.
5. Thoroughly fl ush out the spray gun.
6. Relieve pressure Chapter 7.3.3.
Changing from round jet to fl at jet
7. Unscrew round jet nozzle attachment (2) incl. nozzle insert (3).
8. Unscrew nozzle insert (3) using nozzle spanner (4).
9. Unscrew nozzle nut (5). Remove nozzle screw joint (7) and sealing fi tting (8) from the
nozzle body (6). Thoroughly clean all parts.
10. Insert desired ACF5000 nozzle (11) into the valve housing.
11. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
12. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
13. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
Changing from fl at jet to round jet
7. Unscrew union nut (9) with air cap (10) and ACF5000 nozzle (11).
8. Remove air cap (10).
9. Press ACF5000 nozzle (11) out of air cap (10) by hand. Thoroughly clean all parts.
10. Insert nozzle screw connection (7) and sealing fi tting (8) into nozzle body (6).
11. Screw nozzle nut (5) onto nozzle body (6).
Do not screw on nozzle nut completely. There must be play for the atomizing air
between the nozzle nut and the nozzle body.
12. Screw on nozzle insert (3) using nozzle spanner (4).
13. Screw round jet nozzle attachment (2) with nozzle insert (3) onto spray gun and tighten
by hand.
Содержание GA 5000EACEC
Страница 2: ......
Страница 53: ...53 GA 5000EAC B_05754 1 2 3 4 5 6 7 8 10 9 Y 11 1 OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360922 ...
Страница 106: ...106 GA 5000EAC OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360922 ...
Страница 107: ......