48
GA 5000EAC
B_05776
1
B_05777
2
3
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
7.3.2
SPRAYING
Flat-jet method: Changing the spray jet width
8.
Change the spray jet width by selecting the appropriate nozzle.
By turning the air regulation (1), the spray jet can additionally be adjusted
(IC variant).
Increase or decrease shaping air (EC variant)
Round-jet method
8.
By gently turning the nozzle nut (2), the atomizing air jet can additionally
be adjusted.
Do not fully tighten the nozzle nut:
Do not turn the nozzle nut (2) until it is fl ush with the nozzle body (3).
There must be play for the atomizing air between the nozzle nut and
the nozzle body.
Flow rate
9. The fl ow rate can be reduced by:
- Minimizing the product pressure.
- Use a diff erent nozzle (see Chapter 13).
1. Secure gun (switch off controller) and insert the desired nozzle.
2. Turn on the control unit. See corresponding operating manual.
3. Start up with product supply set to approx. 8 MPa; 80 bar; 1160 psi operating pressure.
See corresponding operating manual.
AirLess spraying
4. Turn both air pressure regulators at the control unit all the way down.
5. Spray on a test object (switch on the controller).
6. Adjust the product pressure and gun air in accordance with the nozzle and object.
AirCoat spraying
7. When IC variant open the air pressure regulator (approx. 0.05–0.25 MPa; 0.5–2.5 bar;
7–36 psi) and adjust for optimal atomization.
When EC variant set shaping and atomizing air on the pressure regulators.