36
B_03054
A
B
C
D
B_03071
X
OPERATING MANUAL
VERSION 06/2013
ORDER NUMBER DOC 2312956
1.
Relieve the pressure of gun and device.
2.
Secure gun (remove the control air hose).
3.
Unscrew union nut (A).
4.
Remove air cap (B).
5.
Push AirCoat nozzle (C) out of air cap (B) by hand and place on nozzle seal (D) the
other way round with the nozzle tip towards the rear.
6.
Fit air cap (B) on nozzle (C).
Note the fl attened parts (X) on the nozzle and in the air cap.
7.
Fit union nut (A) over air cap (B) on spray gun and tighten by hand.
8.
Switch the product pressure back on.
9.
Spray (connect control air hose).
10. When the blockage has been fl ushed out, switch off the spray gun.
11. Relieve the pressure of gun and device.
12. Secure gun (remove the control air hose).
13. Unscrew union nut (A).
14. Remove air cap (B) and push AirCoat nozzle (C) out by hand.
Clean nozzle and nozzle seal and refi t nozzle in spraying position on nozzle seal (D).
15. Fit air cap (B) on nozzle (C).
Note the fl attened parts (X) on the nozzle and in the air cap.
16. Fit union nut (A) over air cap (B) on spray gun and tighten by hand.
17. Connect control air.
Switch the product pressure and the air pressure back on.
Nozzle in spray position
Nozzle in cleaning position
7.5
ELIMINATING NOZZLE CLOGGING
Содержание GA 4000ACIC-R