8.2.3 SAFETY CHECKS AND MAINTENANCE INTERVALS
Every day
Check grounding: see Chapter
.
Check hoses, tubes and couplings: see Chapter
Check the level of separating agent in the separating agent tank and top up, if
necessary, in accordance with Chapter
.
For each decommissioning, the process according to Chapter
must be followed.
If the pump has to be emptied for maintenance work, proceed according to Chapter
.
Weekly
Check spraying system for damage.
Check that the safety fixtures function properly (see Chapter
Yearly or as required
In accordance with DGUV regulation 100-500 Chapter 2.29 and 2.36:
– The liquid ejection devices should be checked by an expert (e.g., WAGNER
service technician) for their safe working conditions as required and at least
every 12 months.
– For shut down devices, the examination can be suspended until the next start-
up.
8.2.3.1 FILLING WITH SEPARATING AGENT
NOTICE
Piston pump dry run!
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
Ensure that the separating agent tank is filled with sufficient separating agent.
To prevent potential transportation issues, the separating
fluid chamber of the pump is not filled at the factory.
Remove the two caps (5), fill up the chamber with separating
agent, as shown in the figure (6), and then replace the caps.
Check the separating fluid level weekly by removing one
cap.
Separating agent: order no. 9992504
Inclination angle of the pump
Maximum permissible tilt of the pump for moving,
transporting, etc. after filling separating agent is ± 30°.
The pump must be vertical during operation.
LEVEL
5
6
C_HE_00006
5
5
5