38
VERSION 06/2018
ORDER NUMBER DOC 2343275
10 TROUBLESHOOTINGTROUBLESHOOTING
Leakage hole (L):
B_07240
O
N
A
E
B_03651
L
Malfunction
Cause
Remedy
No product transportation
Valve does not open.
Check the control air hoses.
Replace piston seals (O).
Travel adjustment set too low
(dosing valve).
Increase the travel adjustment.
Contamination
Valve clogged by product.
Dismantling and cleaning.
Leakage
Cause
Remedy
Product flow at closed valve
setting.
Valve does not close.
Have valve rod (E) and valve seat
replaced by the WAGNER Service
Department.
Air emission on tension nut (A).
Piston seal defective.
Replace O-ring (O).
PTFE valves
Leakage
Cause
Remedy
Product emission from leakage
hole (L).
Valve rod seals defective.
Replace valve rod seals.
Dosing valves: Use FFKM seals as
necessary (see Chapter
Air emission from leakage hole (L). O-ring (N) defective.
Replace O-ring (N).
FFKM valves
Leakage
Cause
Remedy
Separating agent contaminated.
Valve rod seals defective.
Replace separating agent and valve
rod seals: (see Chapter
Use PTFE seals as necessary (see
Chapter
The piston is pushed out of/
falls out of the separating agent
container.
In the case of contaminated
separating agent: valve rod seals
defective.
In the case of foam formation/air
bubbles: O-ring (N) defective.
Replace O-ring (N).
Foam formation/air bubbles in
separating agent.
O-ring (N) defective.