Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
5 Description
Order number 2340851 | Edition 05/2022
21
5.2.2 Fluid Section
The fluid section (9) has been designed as a double diaphragm pump with exchangeable
inlet and outlet valves. Change between spraying mode and product circulation mode using
the relief valve (7).
5.3 PROTECTIVE AND MONITORING EQUIPMENT
WARNING
Overpressure!
Danger to life from bursting device components.
4
Never change the safety valve setting.
The air motor is fitted with a safety valve. The safety valve has been set and sealed at the
factory. In case of pressures over and above the permissible operating pressure, the valve,
which is held with a spring, automatically opens and releases the excess pressure.
The control housing is equipped with noise insulation. Never operate the device without
noise insulation.
5.4 EXTENT OF DELIVERY
Stk
Order no.
Designation
1
2329519
Diaphragm pump Cobra 40-10 consisting of:
Fluid section, air motor, connection elements
1
2329521
Frame-mounted diaphragm pump Cobra 40-10 consisting of:
Fluid section, air motor, connection elements
1
2329523
Diaphragm pump Cobra 40-25 consisting of:
Fluid section, air motor, connection elements
1
2329525
Frame-mounted diaphragm pump Cobra 40-25 consisting of:
Fluid section, air motor, connection elements
The standard equipment includes:
Stk
Order no.
Designation
1
322981
Sign
1
236219
Grounding cable, complete
1
341434
Double open-end wrench
1
See Chapter Declaration of Conformity
Declaration of Conformity
1
2340850
Operating manual, in German
1
See Chapter Languages [
Operating manual in the local lan-
guage
The delivery note shows the exact scope of delivery. Accessories: see Chapter Accessories
[
60].