61
OPERATING MANUAL
VERSION 02/2018
ORDER NUMBER DOC 2366717
7.4.9 SETTING THE HIGH VOLTAGE
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03375
7
8
Procedure
1. Press the "High-voltage" button (7)
to adjust the high voltage.
The LED (8) indicates that high voltage
is selected.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03376
2
21
27
7
2. The high voltage can now be adjusted
using the universal rotary controller (2)
between 5 to 70 kV with a resolution
of 1 kV. The corresponding value is
indicated in the LED display (27).
Above the "High-voltage" button (7) is the "High-voltage" bar graph display (21). If the
control unit is in the ready position, this light strip shows the set value as a dot.