7.4.7 STARTING UP THE VM 5020W CONTROL UNIT
1. Turn switch to position 1.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03372
2. All LEDs on the control unit illuminate for approximately
1 second.
3. The hardware version and the software version are shown
on the display alternately in succession.
B_03373
Hardware version
Software version
4. After a few seconds, the control unit is ready for operation.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03374
Note:
Each starting sequence is concluded by allocating the
saved set data in recipe "R1".
7.4.8 SET AND SAVE RECIPES
Nominal values for the high voltage (kV) and for the spray current limiter (µA) are stored in
a recipe. As standard, the following values are saved in the factory in the 3 storage places
available for recipes:
Recipe No.
Set value - high voltage in kV
Target spray current limitation in µA
R1
70
100
R2
60
100
R3
40
80
Recipes 1-3 can be selected and saved directly with the program buttons "R1", "R2" and "R3".
Once the recipe required has been called up, the individual coating parameters can be
called up and changed using the corresponding selection buttons (see Chapters
,
). When a parameter is changed, the LED on the left of the program button goes out
and indicates to the user that a parameter value has been changed.
Rejecting parameter values
To reuse the originally set values, press the program button briefly. The modified values
are not taken over.
Saving parameter values
However, if the modified values should be saved, press and hold the corresponding
program button for approx. 2 seconds until the LED beside the button starts to flash
quickly. The modified values are then saved.