5.5.1.1 LIMITATIONS FOR 2-CIRCUIT SYSTEMS
Limitations for 2-circuit systems opposite the data in Chapter
Standard
system
2-circuit system
2-circuit system
XL
per circuit
per circuit
2K / 3K / 4K system
2K / 3K / 4K
2K / 3K
Maximum number of A/B/C/D paint and dosing valves 25/10/10/10
10/5/5/–
DN 10: 4/–/–/– *
DN 4: 10/5/5/– *
DN 2.6: –/5/5/– *
Maximum number of A/B/C/D flushing valves
10/5/5/5
5/2/2/–
DN 4: 1/1/1/– *
DN 2.6: –/1/1/– *
Maximum number of guns
4
2
Dump valve for waste separation
(option)
--
External flushing
agent:
- Flushing over a period of time
(option)
(option)
- Flushing with flow monitor
(option)
(option)
- Flushing with flow meter
(option)
--
Booster pump
(option)
--
* More valves for XL version available on request.