1 General information
2015/03
EN-XXX_CIRCOtransfer-30E-50E_TI-MA-BA-150401-3PAW0501 - 99609x7WAG0x-mub-en - V06
5
1.2
About this product
The station is a premounted group of fittings checked for leakage and used to transfer the heat
from the primary or solar circuit to the secondary or storage tank circuit.
It contains important fittings and safety devices for the operation of the installation:
Ball valves with integrated thermometers in the storage tank circuit
(flow and return)
Check valves to avoid involuntary gravity circulation in the flow and return of the primary
and the secondary circuit.
Pressure relief valves to prevent inadmissible overpressures
Pressure gauge to display the system pressure in the solar circuit
Vent valves to easily vent the solar circuit
Fill and drain valves to flush, fill and drain the solar circuit
Two flow meters and electronic temperature sensors for heat quantity balancing
(secondary) and speed control of the pumps depending on the performance
The expansion tank required for operation must be adapted to the size and the requirements of
the installation and must be ordered separately.
The cap-type valve, which is also separately available, allows the expansion tank to be easily
mounted and separated from the solar thermal system.
The wrapping materials are made of recyclable materials and can be disposed of with
recyclable materials.