4   

Operational Instructions — MMC 205 

 
 

On/Off/Species Button: 

When  the  meter  is  Off,  momentarily  pressing  and  releasing  this  button  will  cause  the 
meter  to  turn  On,  and  briefly  display  the  firmware  version,  then  enter  Measurement 
mode.  When the meter is in Measurement mode, and the button is momentarily pressed 

and  released,  it  will  display  the  species  setting  value.  Press  and  release  the  button  again  to  return  to 
Measurement mode. 
 
To turn Off the meter from Measurement mode only, press the On/Off/Species button for 3 seconds and 
then  release.  The  meter  will  also  turn  itself  off  automatically  when  not  in  use  as  described  in  the  auto- 
shutdown section. 
 

Species Setting: 

The species setting can be changed to compensate for a variety of wood species. When measuring another 
species with a Specific Gravity (SG) other than the factory default setting of 0.50 SG, the species setting 
needs to be changed.  Refer to the Species Setting Tables included with your meter to locate the correct 
species  setting  for  your  wood.  If  your  species  setting  is  not  listed,  contact  Wagner  Meters.  The  values 
entered  into  the  MMC  205  meter  omit  the  decimal  point,  so  for  example  the  Douglas  Fir  value  of  0.48 
would be “48” when programming the Species Setting Value. 
 
When  the  meter  is  in  Measurement  mode,  momentarily  pressing  and  releasing  the  On/Off/Species 
button will cause the display to show the current specific gravity setting. Press the button a second time for 3 
seconds and release to enter CHANGE SPECIES MODE, or momentarily press and release the button to 
return to Measurement mode. 
 
When  CHANGE  SPECIES  MODE  has  been  selected,  a  blinking  colon  symbol  (:)  will  appear  on  the 
display.  Momentarily  pressing  the  On/Off/Species  button  again  will  increment  the  selected  specific 
gravity  value  by  01.  The  value  will  go  as  high  as  70,  then  will  wrap  around  to  30  and  continue 
incrementing. When the desired setting has been reached, press button for 3 seconds and release to store 
the value and return to Measurement mode. 
 
Your  commonly  used  species  setting  values  can  be  written  on  the  meter  overlay  decal  in  the  space 
provided  using  a  pencil  or  non-permanent  marker,  and  erased  with  a  swab  dipped  in  isopropyl  alcohol. 
Avoid using a permanent marker because staining of the decal may occur. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MMC 205

Страница 1: ...Moisture Meter Instruction Manual for Wagner Meters Models MMC 205 MMC 210 MMC 220 1 800 634 9961 ...

Страница 2: ...UCTION 3 INSTRUCTIONS MMC 205 4 INSTRUCTIONS MMC 210 5 INSTRUCTIONS MMC 220 6 TAKING MEASUREMENTS 7 FEATURES 8 METER STORAGE 8 METER CALIBRATION 8 METER SPECIFICATIONS 9 FCC COMPLIANCE STATEMENT 10 WARRANTY 11 REPAIR SERVICE 12 ...

Страница 3: ...They are popular with flooring installers woodworkers cabinet and furniture makers contractors and quality assurance inspectors Other important features of hand held moisture meters from Wagner Meters include The Wood Friendly MMC 200 series meters use advanced electromagnetic wave technology to accurately measure wood moisture content1 to a depth of 3 4 inch The MMC 205 can read values from 5 to ...

Страница 4: ...ting is not listed contact Wagner Meters The values entered into the MMC 205 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the On Off Species button will cause the display to show the current specific gravity setting Press the button a second t...

Страница 5: ...with your meter to locate the correct species setting for your wood If your species setting is not listed contact Wagner Meters The values entered into the MMC 210 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the species button will cause the ...

Страница 6: ...r your wood If your species setting is not listed contact Wagner Meters The values entered into the MMC 220 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the species button will cause the display to show the current specific gravity setting Mom...

Страница 7: ...umber thickness is less than the scan depth of the meter an air gap of at least one inch needs to be maintained underneath the wood to prevent erroneous high readings Ensure that there is nothing including your hand under the material you are measuring especially any metal The actual moisture sensing area is a 1 1 2 inch by 2 1 2 inch rectangle on the meter s backside opposite side of the display ...

Страница 8: ... sure to observe proper battery polarity Meter Storage For a long service life it is important to store your meter properly Avoid excessively hot or cold locations and keep the meter in the case provided Do not store the meter in an area with excessive electro magnetic interference such as near an electric motor or where it could be crushed such as in front of a forklift Do not leave the meter in ...

Страница 9: ...seconds Measurement Ranges MMC 205 5 20 MC scaled in 1 increments MMC 210 5 30 MC scaled in 0 1 increments MMC 220 5 30 MC scaled in 0 1 increments up to 80 SG Note If the MMC 220 species setting value selected is more than 80 the maximum moisture content reading attainable will be lower than 30 Density SG Range MMC 205 0 30 to 0 70 SG Density SG Range MMC 210 0 30 to 0 70 SG Density SG Range MMC ...

Страница 10: ...ched to this equipment Finally any changes or modifications to the equipment by the user not expressly approved by the grantee or manufacture could void the user s authority to operate such equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference ...

Страница 11: ...eter should stay in calibration however because Wagner Meters has no control over the manner in which the unit will be used it makes no warranty that the meter will stay in calibration for any specific period of time Wagner Meters recommends returning the unit to the factory for a diagnostic checkup and recalibration in the event the meter is dropped or otherwise damaged or the meter accuracy is s...

Страница 12: ...tion If parts are unavailable to repair we reserve the right to replace the meter with an alternative model with equal or better accuracy and range Wagner Meters 326 Pine Grove Road Rogue River OR 97537 USA Phone 541 582 0541 Fax 541 582 4138 Email sales wagnermeters com Visit Our Moisture Measuring Information Center at www WagnerMeters com 2012WM Wagner Meters Part 500 60200 001 rev C ...