Wagner Meters MMC 205 Скачать руководство пользователя страница 10

10   

FCC Compliance Statement 

 

This  equipment  has  been  tested  and  found  to  comply  within  the  limits  for  a  Class  B  digital  device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in residential installations. 
 
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. 
 
If  this  equipment  does  cause  interference  to  radio  or  television  equipment  reception,  which  can  be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference 
by one or more of the following measures: 
 

 

Reorient or relocate the receiving antenna. 

 

 

Move the equipment away from the receiver. 

 

 

Plug the equipment into an outlet on a circuit different from that to which the receiver is powered. 

 

 

If  necessary,  the  user  should  consult  the  dealer  or  an  experienced  radio/television  technician  for 
additional suggestions. 

 

CAUTION:  

Only equipment certified to comply with Class B (computer input/output devices, terminals, 

printers,  etc.)  should  be  attached  to  this  equipment.    Finally,  any  changes  or  modifications  to  the 
equipment  by  the  user  not  expressly  approved  by  the  grantee  or  manufacture  could  void  the  user's 
authority to operate such equipment.  This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 
 
1)

 

This device may not cause harmful interference, and 

2)

 

This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation. 

 

Canadian Department of Communications  

compliance statement 

 

This equipment does not exceed class B limits per radio noise emissions for digital apparatus, set out in 
the  Radio  Interference  Regulation  of  the  Canadian  Department  of  communications.  Operation  in  a 
residential  area  may  cause  unacceptable  interference  to  radio  and  TV  reception,  requiring  the  owner  or 
operator to take whatever steps are necessary to correct the interference. 
 

Avis de conformité aux normes du ministère des

 

Communications du Canada

 

 
Cet  équipement  ne  dépasse  pas  les  limites  de  Classe  B  d’émission  de  bruits  radioélectriques  pour  les 
appareils numériques, telles que prescrites par le Réglement sur le brouillage radioélectrique établi par le 
ministère  des  Communications  du  Canada.  L’exploitation  faite  en  milieu  résidentiel  peut  entrainer  le 
brouillage  des  réceptions  radio  et  télé,  ce  qui  obligerait  le  propriétaire  ou  l’opérateur  à  prendre  les 
dispositions nécessaires pour en éliminer les causes. 
 

Содержание MMC 205

Страница 1: ...Moisture Meter Instruction Manual for Wagner Meters Models MMC 205 MMC 210 MMC 220 1 800 634 9961 ...

Страница 2: ...UCTION 3 INSTRUCTIONS MMC 205 4 INSTRUCTIONS MMC 210 5 INSTRUCTIONS MMC 220 6 TAKING MEASUREMENTS 7 FEATURES 8 METER STORAGE 8 METER CALIBRATION 8 METER SPECIFICATIONS 9 FCC COMPLIANCE STATEMENT 10 WARRANTY 11 REPAIR SERVICE 12 ...

Страница 3: ...They are popular with flooring installers woodworkers cabinet and furniture makers contractors and quality assurance inspectors Other important features of hand held moisture meters from Wagner Meters include The Wood Friendly MMC 200 series meters use advanced electromagnetic wave technology to accurately measure wood moisture content1 to a depth of 3 4 inch The MMC 205 can read values from 5 to ...

Страница 4: ...ting is not listed contact Wagner Meters The values entered into the MMC 205 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the On Off Species button will cause the display to show the current specific gravity setting Press the button a second t...

Страница 5: ...with your meter to locate the correct species setting for your wood If your species setting is not listed contact Wagner Meters The values entered into the MMC 210 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the species button will cause the ...

Страница 6: ...r your wood If your species setting is not listed contact Wagner Meters The values entered into the MMC 220 meter omit the decimal point so for example the Douglas Fir value of 0 48 would be 48 when programming the Species Setting Value When the meter is in Measurement mode momentarily pressing and releasing the species button will cause the display to show the current specific gravity setting Mom...

Страница 7: ...umber thickness is less than the scan depth of the meter an air gap of at least one inch needs to be maintained underneath the wood to prevent erroneous high readings Ensure that there is nothing including your hand under the material you are measuring especially any metal The actual moisture sensing area is a 1 1 2 inch by 2 1 2 inch rectangle on the meter s backside opposite side of the display ...

Страница 8: ... sure to observe proper battery polarity Meter Storage For a long service life it is important to store your meter properly Avoid excessively hot or cold locations and keep the meter in the case provided Do not store the meter in an area with excessive electro magnetic interference such as near an electric motor or where it could be crushed such as in front of a forklift Do not leave the meter in ...

Страница 9: ...seconds Measurement Ranges MMC 205 5 20 MC scaled in 1 increments MMC 210 5 30 MC scaled in 0 1 increments MMC 220 5 30 MC scaled in 0 1 increments up to 80 SG Note If the MMC 220 species setting value selected is more than 80 the maximum moisture content reading attainable will be lower than 30 Density SG Range MMC 205 0 30 to 0 70 SG Density SG Range MMC 210 0 30 to 0 70 SG Density SG Range MMC ...

Страница 10: ...ched to this equipment Finally any changes or modifications to the equipment by the user not expressly approved by the grantee or manufacture could void the user s authority to operate such equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference ...

Страница 11: ...eter should stay in calibration however because Wagner Meters has no control over the manner in which the unit will be used it makes no warranty that the meter will stay in calibration for any specific period of time Wagner Meters recommends returning the unit to the factory for a diagnostic checkup and recalibration in the event the meter is dropped or otherwise damaged or the meter accuracy is s...

Страница 12: ...tion If parts are unavailable to repair we reserve the right to replace the meter with an alternative model with equal or better accuracy and range Wagner Meters 326 Pine Grove Road Rogue River OR 97537 USA Phone 541 582 0541 Fax 541 582 4138 Email sales wagnermeters com Visit Our Moisture Measuring Information Center at www WagnerMeters com 2012WM Wagner Meters Part 500 60200 001 rev C ...

Отзывы: