Liquid Soap and Foam Soap Dispenser
Disinfectant Dispenser

User Guide for Mounting and Commissioning

5/20

ENGLISH

Safety information

During mounting

 

The product may only be installed by 

qualified personnel with relevant techni-

cal knowledge.

 

Observe the applicable national safety 

regulations when handling electrically 

operated tools.

 

Wear prescribed protective equip-

ment such as safety glasses and work 

gloves.

 

Be aware of electrical cables, water 

pipes or similar when drilling the fixing 

holes.

 

Remove drilling dust and other contami-

nation after mounting.  

Observe the safety and usage informa-

tion for the use of cleaning agents in 

the associated 

User Guide for Mainte-

nance and Care

.

During commissioning

 

Only use the permissible operating 

fluids. You will find information on this 

in the associated 

User Guide for Main-

tenance and Care

.

Mounting and  

commissioning

 

Observe the safety information listed 

above, the mounting information from 

page 10 and the commissioning 

information from page 15.

 

The illustrations and descriptions show 

examples of the mounting and commis-

sioning of the surface-mounted variant. 

This guide applies generally to flush-

mounted, washbasin or behind-mirror 

installation as well as units with several 

Modules.

Accessories, spare parts, 

operating fluids and further 

product information

The accessories, spare parts, operating 

fluids and further product information for 

this product are available online at  

www wagner-ewar de/service 

Liability and warranty

The warranty is rendered void in the event 

of improper installation and commissioning 

as well as due to the use of unapproved 

operating fluids or non-genuine Wagner 

EWAR spare parts.

Содержание WP 101

Страница 1: ...1 101 1 101 7 WP 102 102 1 102 7 WP 103 WP 107 WP 173 173 1 173 5 173 7 WP 174 174 2 174 5 174 7 WP 208 208 5 208 7 WP 575 WP 585 585 7 PP 17 PP 101 101 7 PP 102 102 7 PP 103 PP 107 WH 2 Anleitung f r...

Страница 2: ...er bzw das Entfernen hier enthaltenen Texts oder ungewollte bzw durch den Gebrauch des Materials entstehende Besch digungen All rights reserved Protected within the limits permitted by international l...

Страница 3: ...r Disinfectant Dispenser User Guide for Mounting and Commissioning 3 20 DEUTSCH 4 ENGLISH 5 FRAN AISE 6 T RK E 7 LIEFERUMFANG SCOPE OF DELIVERY 8 MONTAGE MOUNTING 10 INBETRIEBNAHME COMMISSIONING 16 IN...

Страница 4: ...i der Inbetriebnahme Verwenden Sie nur die zul ssigen Betriebsmittel Hinweise hierzu finden Sie in der zugeh rigen Anleitung zur Wartung und Pflege Montage und Inbetriebnahme Beachten Sie die oben auf...

Страница 5: ...le operating fluids You will find information on this in the associated User Guide for Main tenance and Care Mounting and commissioning Observe the safety information listed above the mounting informa...

Страница 6: ...ions relatives ce sujet figurent dans les instructions d entretien et de mainte nance correspondantes Montage et mise en service Respecter les consignes de s curit ci dessus les instructions de montag...

Страница 7: ...en i letim malzeme lerini kullan n Bu konudaki bilgileri ilgili bak m ve onar m talimatlar nda bulabilirsiniz Montaj ve devreye alma Yukar da listelenen g venlik talimatla r n 10 sayfasindan itibaren...

Страница 8: ...n Sie hierzu Ihren Liefer schein The scope of delivery depends on the ordered device type Please check your delivery note Geh use Housing 1 4 3 2 1 Aufputz Montage mit 1 2 oder 3 Einheiten Surface mou...

Страница 9: ...ml 3 Desinfektionsmittelpumpe mit Tank 700 950 ml Disinfectant pump with tank 700 950 ml 4 Aufstecktank 850 ml Plug in tank 850 ml 5 Einwegflasche Fl ssigseife 950 500 ml Liquid soap disposable bottl...

Страница 10: ...pen und Montageart Types and mounting A mm B mm T mm H mm X 1 mm 1 Aufputzmontage Surface mounting 150 2 Unterputzmontage Flush mounting 150 450 110 3 Montage hinter Spiegel Mounting behind mirror 75...

Страница 11: ...H 1 I 1 1 WP101 1 7 70 270 35 215 20 35 72 1 WP102 1 7 WP103 80 298 5 35 5 243 20 40 72 1 WP107 70 170 40 105 25 35 77 2 WP575 298 298 74 5 205 18 5 19 260 30 5 149 2 WP585 7 218 298 74 5 205 18 5 19...

Страница 12: ...mm A F G B D E C 2 3 1 A B C H F G F I D F A B D C E H 1 Montage im Schrank Mounting in cabinet 2 Montage hinter Spiegel Mounting behind mirror 3 Unterputzmontage Flush mounting Typ Type A B C D E F G...

Страница 13: ...age auf Seite 11 Mount housing on the wall back wall using the enclosed installation material see Installation notes on page 10 resp Drilling scheme surface mount ing on page 11 Unterputzmontage Flush...

Страница 14: ...ren nach vorne biegen 2 Pumpe I bzw Pumpe mit Tank II von oben in die F hrung mit den Klemmla schen einschieben Bei Seifenschaumpumpe Zus tzlich den Zughebel ziehen Sicherungslaschen B nach innen bieg...

Страница 15: ...bis die Flasche richtig positioniert ist Place dispenser bottle tank into pump connection and rotate it in straight until it stops Surface mounting Indentation in end position right III Place the foa...

Страница 16: ...fernen 1 NOTICE Fill only with the operating medium intended and suitable for the dispenser see User Guide for Mainte nance and Care 2 Open tank cap and fill in liquid soap or disinfectant 3 Close cap...

Страница 17: ...move any protective film that may still be attached Mit der Hand den Hebel unten am Spender ziehen Bei der ersten Inbe triebnahme k nnen mehrere Bet tigun gen erforderlich sein bis Fl ssigkeit gespend...

Страница 18: ...Fl ssigseifen und Seifenschaumspender Desinfektionsmittelspender 18 20 Anleitung f r Montage und Inbetriebnahme Notizen Notes...

Страница 19: ...Liquid Soap and Foam Soap Dispenser Disinfectant Dispenser User Guide for Mounting and Commissioning 19 20 Notizen Notes...

Страница 20: ...t Wagner GmbH Co KG Ernst Abbe Stra e 21 D 72770 Reutlingen www wagner ewar de info wagner ewar de 49 7121 515390 Bestell Nr Order No 009014 Ausgabe Edition 01 2024 nderungen vorbehalten Subject to ch...

Отзывы: