background image

 

2019 

 

Part 2: Operation & Maintenance Instructions for  

 WAGENER SPARKY CA - Woodfire            

 

 

Message to the Owner 

Thank you for purchasing a New Zealand designed and made Wagener Stove. 

With care and common sense your Wagener Sparky CA will give you many years of trouble free service.  

We recommend an annual safety check of flues, bricks, door seals, door catches, air controls and the like. 

 

WARNINGS AND CAUTIONS 

 

1.

 

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.  

 

2.

 

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE. 

 

3.

 

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS 

APPLIANCE WHEN IT IS OPERATING. 

 

4.

 

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES. 

 

5.

 

WARNING: DO NOT OPERATE THIS APPLIANCE AS AN OPEN FIRE. IT IS NOT TESTED TO BE 

USED IN THIS WAY AND WILL BE CONSIDERED AS BREACHING AS/NZS2918:2001. 

 

6.

 

WARNING: OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR. 

 

7.

 

CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS. 

 

8.

 

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN 

ACCORDANCE WITH THESE INSTRUCTIONS. 

 

9.

 

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE 

HAZARDOUS TO THE ENVIRONMENT AND DETRIMENTAL TO YOUR APPLIANCE. 

 

 

Further Cautions & Over Firing 

 

Never run Sparky CA with the door ajar or open. This will cause over firing and damage to your 

stove & flue which will NOT be covered by warranty as well as being potentially dangerous. 

SIGNS OF OVER FIRING: Flue turns red hot, stove “roars”, cooktop surface becomes red hot. 

 

POSSIBLE CAUSE OF OVER FIRING

  

REMEDY

 

 

1.

 

Excess flue length/ windy conditions   

Move Air Control to reduce or close air supply 

2.

 

Appliance run with door ajar  

 

Close the door 

3.

 

Faulty door seals 

 

 

 

Replace faulty door seals 

4.

 

Full load of very dry, small wood 

 

Don’t load excess quantities of fuel 

5.

 

Dirty flue catches fire  

 

 

Close Air Supply. Call fire brigade if necessary. 

                                                                            Inspect & Clean Flue when cold. 

                                                                        

Sparky CA is HOT while in operation and caution is required as contact may cause burns. 

 

CREOSOTE OR SOOT FIRE

:  

In the unlikely event of a soot or creosote fire occurring see Remedy 5 above. 

 

Содержание Sparky CA

Страница 1: ...ordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variation from these installation instructions or any doubts about them must be...

Страница 2: ...instructions on pages 4 5 6 NOTE A purpose designed and tested petite flue system is available for Sparky CA using a 100 150 200mm system with a reduced flue shield and ceiling plate Flue Shield Spark...

Страница 3: ...he AS NZS 2918 2001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER Sparky CA 100 370 370 797 797 865 485 460 540...

Страница 4: ...flue that drives the Sparky CA We recommend 4 2 metres of flue 2019 4 COWL 200MM OUTER CASING PERLIN FLASHING Inner casing 200mm above roof line 100MM FLUE PIPE 150MM INNER CASING CEILING PLATE CERAM...

Страница 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Wood Fire s Flue Spigot Check that the Wood Fire s location allows the OUTER CASING to clear all the structur...

Страница 6: ...OUTER CASING into the bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER...

Страница 7: ...FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS 9 CAUTION...

Страница 8: ...ht the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or 3 small logs of wood and close the door Do not adjust the air control 3 To add...

Страница 9: ...in over firing Sparky CA causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect comple...

Отзывы: