100mm / 200mm Free Standing Woodfire Flue Kit 

Installation Instructions 

(continued)

 

 

 

 

Note

 that the INNER CASING MUST extend 200mm above roof penetration.  

 

NB

: Do not secure the OUTER CASING SLIP EXTENSION onto the OUTER CASING, as a final adjustment 

will be required when fitting cowl assembly. See paragraph 11.  

 

5. Fix an appropriate flashing around the OUTER CASING to seal onto the roofing material. Refer to the 

manufacturer’s recommendations for correct fitting. 

NB

: On iron roofs, fixings such as metal angle brackets 

(approximately 25mm x 25mm) can be fitted under the flashing to securely fix the roof to OUTER CASING.  

 

6. Place CEILING PLATE over Wood Fire’s Flue Spigot, ensuring the folded edges are facing the ceiling.   

 

7. Position bottom length of FLUE PIPE (crimped end downwards) into Wood Fire Flue Spigot.  

Refer to the supplier of the Wood Fire and use the flue pipe sealant recommended.  

 

8. Assemble FLUE PIPES together ensuring seams are straight, offsetting the seams will ensure a neat fit. FLUE 

PIPES 

must 

be assembled with crimped ends down (towards Wood Fire). Secure each joint with a minimum 

of three Monel Steel Rivets equally spaced around the joint. If using HI-THERM FLUE PIPE the protective 

wrapping should be left on the FLUE PIPE during installation.   

 

9. From the roof lower FLUE PIPE through OUTER CASING into the bottom FLUE PIPE securing the 3 

Monel rivets.    

 

10. Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and 

then from the roof slide the INNER CASING into the OUTER CASING until the brackets rest on to the 

internal swage ring of the OUTER CASING, this will ensure the INNER CASING is the correct 12mm above 

ceiling level.  

Check the INNER CASING when correctly positioned extends a minimum of 200mm above the roof 

penetration.   

 

11. Before securing the OUTER CASING SLIP EXTENSION to the OUTER CASING with 3 rivets, ensure the 

FLUE PIPE is either flush or extends above the top of the OUTER CASING SLIP EXTENSION by no more 

than 15mm. Adjust SLIP EXTENSION to obtain this measurement.  

 

12. Push CASING COVER (with spigot inside FLUE PIPE) down onto the OUTER CASING SLIP 

EXTENSION. The 3 locating brackets with holes must be on the outside of the OUTER CASING SLIP 

EXTENSION and are secured using 3 rivets.   

 

13. Fit COWL but do not secure, as removal for flue cleaning will be necessary. Deform or ovalise the stub of 

the COWL to ensure it is a tight friction fit.   

 

14. Fasten CELING PLATE to ceiling using screws and ceramic spacers required. Ensure an even air gap 

around FLUE PIPE when fixing. Remove protective plastic from CEILING PLATE 

N.B

 12mm air gap between 

ceiling plate and ceiling must be maintained.  

 

 15. Fit the flue shield to the flue pipe as per fitting instructions supplied with the flue shield kit. 

 

 16. Please leave all instructions with the owner.   

Содержание Sparky CA

Страница 1: ...ordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variation from these installation instructions or any doubts about them must be...

Страница 2: ...instructions on pages 4 5 6 NOTE A purpose designed and tested petite flue system is available for Sparky CA using a 100 150 200mm system with a reduced flue shield and ceiling plate Flue Shield Spark...

Страница 3: ...he AS NZS 2918 2001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER Sparky CA 100 370 370 797 797 865 485 460 540...

Страница 4: ...flue that drives the Sparky CA We recommend 4 2 metres of flue 2019 4 COWL 200MM OUTER CASING PERLIN FLASHING Inner casing 200mm above roof line 100MM FLUE PIPE 150MM INNER CASING CEILING PLATE CERAM...

Страница 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Wood Fire s Flue Spigot Check that the Wood Fire s location allows the OUTER CASING to clear all the structur...

Страница 6: ...OUTER CASING into the bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER...

Страница 7: ...FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS 9 CAUTION...

Страница 8: ...ht the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or 3 small logs of wood and close the door Do not adjust the air control 3 To add...

Страница 9: ...in over firing Sparky CA causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect comple...

Отзывы: