6
Part 2: OPERATION & MAINTENANCE
INSTRUCTIONS FOR THE BUTLER MULTI 3/05
Message to the Owner
Thank you for purchasing the Butler Multi.
With care and common sense the Butler Multi will give you many years of trouble free service.
We recommend an annual safety check of flues, bricks, door seals, door catches, air controls and the like.
WARNINGS AND CAUTIONS
1.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.
2.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE.
3.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS
APPLIANCE WHEN IT IS OPERATING.
4.
WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.
5.
WARNING: DO NOT OPERATE THIS APPLIANCE AS AN OPEN FIRE. IT IS NOT TESTED TO BE
USED IN THIS WAY AND WILL BE CONSIDERED AS BREACHING AS/NZS2918:2001.
6.
WARNING: OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR.
7.
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS.
8.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS.
9.
CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE
HAZARDOUS.
Further Cautions & Over Firing
Never use the Butler Multi with the door ajar or open. This will cause over firing and damage to
your stove & flue which will NOT be covered by warranty as well as being potentially dangerous.
SIGNS OF OVER FIRING: Flue turns red hot and stove “roars”.
POSSIBLE CAUSE OF OVER FIRING
REMEDY
1.
Excess flue length/ windy conditions
Move Air Control to reduce or close air supply
2.
Door Ajar
Close door
3.
Faulty door seal
Replace faulty door seals
4.
Full load of very dry, small wood
Don’t load excess fuel
5.
Dirty flue catches fire
Close Air Supply. Call fire brigade if necessary.
Inspect & Clean Flue when cold.
The Butler Multi is HOT while in operation and contact may cause burns.
CREOSOTE OR SOOT FIRE: In the unlikely event of a soot or creosote fire occurring see Remedy 5 above.