3
BUTLER MULTI WET 6KW
Fitted with a standard 6kw “Lion” Wet Back only
Wet Installation Clearances AS/NZ Standard 2918:2001
Estimated Heat Output 8kw (depending on fuel used)
Estimated Hot Water Output 6kw
Minimum clearance to
Combustible Surfaces
A
B
C
D
E
F
G
H
With double stainless steel
Flue shield to unprotected
mm)
wall
50mm
50mm 300mm 175mm 25mm 190mm 210mm 240mm
As above 12mm Eterpan LD
board spaced 25mm off wall
37mm
37mm
As above with sheet metal any
type 0.5mm or thicker spaced
25mm off the wall.
25mm
25mm
Ash Hearth Floor
Protection must
extend under the
stove and forward
300mm extending
200mm either side of
the door opening
Other screening materials are available and clearance factors can be calculated to the AS/NZS 2918:2001.
Please ask your retailer or contact Wagener Stoves if you need further advice.
150
150
320
660mm
585m
770mm
770mm
25mm
25mm
25mm
wetback
wetback
pipes
pipes
wetback
pipes
150
320
800mm
725
mm
910mm
910mm
E
H
E
H
C
670
D
B
G
A
C
Floor Protector
Ash
Hearth only
320
TOP
TOP
F
140
*
* 1. One side wall clearance can be reduced
to 25mm by rotating the
fl
ue shield 45 deg
2. Bench height side wall only (not above top
of heater) clearance 25mm.
*(185mm)
870
50
50
300
600
520
2017