manualshive.com logo in svg
background image

Item No. : 3744 (12V DC Input)

3744-4 (24V DC Input)

3744-8 (48V DC Input)

Proline 5000 

 

AC to DC Inverter

User’s Manual

Please visit our website for the latest information on this product.

RoHS

compliant

Содержание Proline-5000 3744

Страница 1: ...Item No 3744 12V DC Input 3744 4 24V DC Input 3744 8 48V DC Input Proline 5000 AC to DC Inverter User s Manual Please visit our website for the latest information on this product RoHS compliant...

Страница 2: ...Output AC Terminals 6 Remote ON OFF Switch Connection 6 Power Inverter Output Waveform 6 Inverter Output Characteristics 7 Rear Panel 7 High Speed Cooling Fan 7 Negative DC Input and Positive DC Input...

Страница 3: ...onnecting an Inverter 12 General information 12 Ground Terminal Wire Requirements 12 Cable Preparation 12 Inverter to Battery Connection Procedure 13 Charging the Battery Bank 14 Regular Loss of Comme...

Страница 4: ...ing fumes from flooded lead acid batteries Keep well ventilated this device generates heat Do not continuously operate your inverter at more than its rated output wattage Incorrect battery polarity wi...

Страница 5: ...e equipment All Modified Sine Wave MSW inverters may not properly operate some appliances with either speed control features or dimmer controls Some appliance GFCI power cords will not operate properl...

Страница 6: ...verter These are used to help diagnose problems if they occur Volts Display The volts display is the measurement of the voltage at the DC terminals of the inverter not actual battery voltage During hi...

Страница 7: ...nnection to distributed wiring that has multiple AC outlets Any wiring that is directly connected must be 10 gauge or larger Facing the front panel the terminals are Top Middle Bottom Live Black Neutr...

Страница 8: ...gh Speed Cooling Fan Positive DC Input Terminal High Speed Cooling Fan Fans operate automatically when the internal temperature of the inverter requires cooling Always allow free air flow Do not block...

Страница 9: ...otorized appliances will cause Do not exceed the surge rating of this inverter 5 000 watts this can cause immediate overload shut down At 5 000 watts continuous output this inverter requires a DC powe...

Страница 10: ...ged at a 1 amp rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery st...

Страница 11: ...ries are flooded type they freely vent hydrogen and oxygen while under charging and heavy discharge They must be vented to outside air to prevent accumulation of explosive gases If the batteries are t...

Страница 12: ...protection Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 12V DC Input Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 24V DC Input Safety Ground 48V DC Input...

Страница 13: ...to the positive terminal of the battery bank Use a length of string and follow the route the cables will follow Measure the length of string and then determine the correct gauge cable required for the...

Страница 14: ...erminals on the rear of the inverter 4 Tighten the retaining nuts 5 Connect all fuses end positive cable ring terminals to the positive battery bank terminal 6 Carefully tighten the retaining nuts DO...

Страница 15: ...charger manual s s WARNING THERE IS DANGER OF EXPLOSION DO NOT CONNECT OR DISCONNECT CHARGER CABLES DIRECTLY AFTER BATTERY DISCHARGE OR RECHARGE MAKE SURE THAT THE BATTERY BANK AREA IS WELL VENTED BE...

Страница 16: ...ed value Recharge or replace battery Equipment being operated draws too much power Cable gauge may be inadequate use heavier cables Inverter is too hot thermal shut down mode Allow inverter to cool Ch...

Страница 17: ...DC 0 2A DC Battery low alarm 3744 10 5V 0 5V DC 3744 4 21 0V 1 0V DC 3744 8 42 0V 2 0V DC Battery low shutdown 3744 9 5V 0 5V DC 3744 4 20 0V 1 0V DC 3744 8 40 0V 2 0V DC AC output sockets 3 US standa...

Страница 18: ...battery negative to inverter negative Use this Total Cable Length to determine the correct cable gauge in table in Appendix A Fuse Battery Bank INVERTER Positive Cable Positive Cable Negative Cable To...

Страница 19: ...warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no cl...

Страница 20: ...CA 94544 U S A Tel 1 510 471 9221 U S Canada Toll Free 1 800 231 5806 customerservice wagan com www wagan com 2016 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used b...

Отзывы: