3.  Once the two Lithium Cube Power Stations are connected, turn on the AC Power Button 

on each unit, and you can charge electrical devices through the AC output socket on 

the Parallel Cable.

*Real-time AC output wattage shows on both units, indicating a successful connection.

 Notice:

1.  For parallel connections, please use Wagan’s official parallel connectors. Wagan will 

not be responsible for any safety accident resulting from the use of cables not approved 

by Wagan.

 

To prevent electric shock, please do not plug any conductive objects into the 

parallel ports.

2.  Please make sure that the AC output is off before connecting the two units in parallel.

 

If the AC output has been turned on before plugging the parallel connectors, it is 

possible to generate electric sparks and damage the parallel ports.

3.  Please note that when the Lithium Cube is in UPS mode, the parallel connection is 

automatically disabled.

4.  Upon connecting the two units in parallel, one unit with lower power will automatically 

shut itself down when its power is exhausted, which will disable the parallel connection 

and return the AC output to 1800W.

PARALLEL

CONNECTION

GROUND

PARALLEL

CONNECTION

GROUND

AC Output Enabled

Green: Earth Wire

Black: Neutral Wire

Red: Live Wire

AC Socket

Содержание LITHIUM CUBE EX18

Страница 1: ...Item No 8837 User s Manual...

Страница 2: ...e severely reduced or the product may cease to work WARNINGS identify important safety concerns when operating this equipment Failure to follow these warnings could result in personal injury or loss o...

Страница 3: ...place it in an open area keep it away from combustible materials and people and dispose of it in accordance with local laws and regulations Do not move the product during use Movements may lead to poo...

Страница 4: ...Anderson Input Port Anderson Output Port 12V DC Output DC Power Button UPS Overload Circuit Breaker AC Charging Input Port PARALLEL CONNECTION GROUND Main Power Button LCD Screen USB A Output Ports US...

Страница 5: ...WHAT S INCLUDED Lithium Cube AC Charging Cable DC Charging Cable User s Manual LCD DISPLAY Battery Level Remaining Charge Discharge Time Input Power Output Power Battery Failure Warning High Temperat...

Страница 6: ...age if there is an inadvertent short Users can charge the product through the cigarette lighter port Be sure to start the vehicle before using the DC Charging Cable to reduce the risk of depleting you...

Страница 7: ...series If only two panels are connected you must connect the jumper cable to the third cable set in order for the panels to charge You can connect this cable to any cable set on the panel side of the...

Страница 8: ...observe the power indicator 4 After appliance use turn OFF the AC power button 5 Remove AC appliance plug s from the AC outlets on the Lithium Cube 6 Recharge the Lithium Cube as soon as convenient No...

Страница 9: ...approved by Wagan To prevent electric shock please do not plug any conductive objects into the parallel ports 2 Please make sure that the AC output is off before connecting the two units in parallel I...

Страница 10: ...s data servers and workstations It is recommended that you test and confirm the compatibility of Lithium Cube with your devices before using the UPS function To avoid overload protection we recommend...

Страница 11: ...harging ports the product supports most fast charging protocols Note When the USB output exceeds 5W the USB output wattage will be displayed on the screen Output voltage is reduced to 5V when both a f...

Страница 12: ...can be extended if charging cable is connected to the Lithium Cube AC OPERATING TIME AC Powered Products Watts Estimated Run time 1 Clock Radio 10 115 hours WiFi Router 15 77 hours DVD Player 50 23 ho...

Страница 13: ...an environment with a temperature between 68 F to 86 F away from water intense heat and other sharp objects If the remaining battery is less than 1 after you finish using the product please re charge...

Страница 14: ...works properly High Temperature Charge Protection Let the unit cool down for 2hrs before recharge Battery Failure Contact Wagan Support Team No response after pressing the main power button System Hal...

Страница 15: ...d device and restart the unit Do not use electrical devices that exceed the rated power of unit USB C Output Failure USB C Overload Protection USB C output will be resumed automati cally after you rem...

Страница 16: ...anel s with a voltage of 11V 70V DC Solar Input Over Current Please use solar panel s within the input wattage of 600W 9 RECYCLING DISPOSAL If conditions permit make sure that the battery is fully dis...

Страница 17: ...onnection Supports 2 Lithium Cube 8837 to parallel Protection Over Voltage Protection Overload Protection Over Temperature Protection Short Circuit Protection Low Tempera ture Protection Low Voltage P...

Страница 18: ...ironmental Operating Temperature Optimal Operation Temperature 68 F 86 F Storage Temperature 4 F 113 F Charging Temperature 32 F 113 F DIscharging Temperature 4 F 113 F 11 OPTIONAL ACCESSORIES AA5476...

Страница 19: ...s expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of perfor...

Страница 20: ...gan com US CAN Toll Free 1 800 231 5806 Telephone 1 510 471 9221 31088 San Clemente Street Hayward CA 94544 U S A 2023 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks of...

Отзывы: