Using the battery charger
PerfectCharge W2000
40
Disconnecting the battery charger
➤
Plug the power plug (fig.
8
1, page 5) into an earthed and
correctly fused 230 V power socket.
Consult a specialist if you are uncertain.
➤
Connect the red positive terminal of the charger to the positive
terminal of the battery () (fig.
6
A, page 4).
I
Note
The positive terminal is not connected to the bodywork when it is
connected.
➤
Connect the black negative terminal of the charger to the
negative terminal of the battery (marked –) (fig.
6
B, page 4).
I
Note
The negative terminal is connected to the bodywork when it is
connected.
✓
if the polarity is reversed, the red “Reverse polarity” LED
(fig.
7
1, page 5) lights up. If this happens, swap over the
connections.
✓
The charger is ready to charge the connected battery or provide
a jump start.
6.2
Charging the battery
The charger can charge maintenance-free (gel and fleece) and
non-maintenance-free lead acid batteries (wet) with a rated voltage
of 12 V or 24 V.
a
Caution – danger of explosions
Set the correct charge voltage. Do not use the device on batteries
with other rated voltages.
I
Note
You can interrupt the charging process at any time.