8
Fault detection
Error
No output voltage
Alarm sounds during operation
Unit switches on/off frequently
When turning on the consumer, the
Pocket Power switches off
Cause
Cigarette lighter is turned on via the
ignition
Battery voltage lower than10 V
(720-012PP) or 20 V (720-024PP)
Thermal overload
Defective fuse either within the Inverter
or the car fuse
The battery voltage is below 10.5 V
(720-012PP) or 21.0 V (720-024PP)
Bad contact in the cigarette lighter
socket under load condition
Max. load is too high
Initial current load too high
Correction
Turn on the ignition
Charge the battery (start the engine)
Switch off the consumer cool down
the Inverter and improve air circulation
Replace the fuse by the help of an expert
Charge the battery
Clean the contacts
Reduce the load
Check power specification and
Verify with max. power of the inverter
Technical data
Ref. No.
720-012PP
720-024PP
Input voltage
12 V DC
24 V DC
Continuous output power
150 W
150 W
Surge output power
300 W
300 W
Max. output current
18 A
10 A
Output voltage
230 V AC pure sine wave
Output frequency
50 Hz
No load pover consumption
0,5 A
0,3 A
Input voltage range
10-15 V
20-30 V
Battery low alarm
10,5 V
21 V
Battery shut down
10 V
20 V
Operatin environment temp.
50° C ± 5° C
Heat dissipation
housing
Dimensions (mm)
190 x 120 x 62
Weight (kg)
1,2
Subject to changes in the interest of technical progress, and availability.
If there are any questions,
please ask for detailed informations:
WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten
Tel. +49-25 72/8 79-1 91 · Fax +49-25 72/8 79-3 91
http://www.waeco.de
E-Mail: