MagicSafe MS670
Programming MagicSafe
47
Modifying selected function
➤
Insert the electronic key in the key holder in order to modify the value of
the selected function.
✓
If the factory setting is “On”, the value is set to “Off” and vice versa.
✓
The alarm siren emits an acoustic signal, and the LED on the control
device flashes once.
Function
Factory setting
Programming
Acoustic signals
Off
The following acoustic signals are emitted:
Activating: 2 brief signals
Deactivating: 3 brief signals
Deactivating when the alarm has been triggered:
5 brief signals
Optical signals
Off
This function enables opticals signals via the
hazard lights system, when the alarm system is
connected with it.
When the fucntion is programmed, the function
“Optical signals during activation/deactivation”
cannot be used.
Optical signals during
activation/deactivation
Off
This function can only be activated for vehicles
which do not emit any optical signals (e. g.
indicator) during opening or closing.
Passive alarm
Off
This function automatically activates the alarm
system 60 seconds after the ignition has been
switched off.
When this function is activated, the convenience
output and the ultrasonic sensors are
deactivated.
Convenience output
Off
The factory setting switches the convenience
output to negative so that an external system can
be connected.
The convenience output can be programmed in
such a way that the windows will be closed
automatically as soon as the vehicle has a
convenience control.
_MS-670.book Seite 47 Donnerstag, 8. Mai 2008 4:55 16