DIY-12
Electrical connections
33
7.2
Connecting the alarm system
You will find a summary of the wiring in the circuit diagram in fig.
5
, page 3.
➤
Connect the
black cable
to earth (terminal -31).
➤
Connect the
red cable
to a cable with a per12 V charge
(te30).
➤
Connect the
yellow cable
to a connected positive terminal (terminal 15).
➤
Optionally, connect the
green cable
to the bonnet contact switch
(accessory).
➤
Optionally, connect the door contact switch kit (optional accessory) to the
green cable
as shown in the circuit diagram.
➤
If you want to deactivate the
acknowledgement tones
when you arm or
disarm
the alarm system
, connect the
grey cable
to the black cable or
connect it to earth.
No.
Explanation
1
Terminal 30, +12 V
2
Terminal 15, sw12 V
3
Compact alarm unit
4
Cable for deactivating acknowledgement tones
5
Status LED
6
Cable to bonnet contact switch
7
Door contact switch kit
8
Original cable to boot contact switch
9
Original cable to door contact switch
rt
Red
ge
Yellow
gn
Green
sw Black
gr
Grey
DIY-12.book Seite 33 Freitag, 24. Februar 2006 3:51 15