8. Loose the screws either side of the
thermostat
7. Carefully remove the
thermostat capillary probe
1. Locate the thermostat housing
inside the fridge and remove
the light button
2. Remove the front screw
3. Remove the LED cover
4. Loosen the rear screw, this doesn’t
have to be removed
5. Pull the thermostat housing
forward. It should now come
away from the wall
6. Disconnect the black plug
9. Remove the thermostat control knob
10. Reverse steps to replace.
Please note that the thermostat
probe must not be cut and must
go into the pipe in the wall of the
insulation not the insulation!
Changing the Thermostat
- Repair Guide
www.dometic-waeco.com • [email protected]