6.3 Ventilation
The refrigerator must be installed so that the warm air produced can easily fl ow
away. Therefore make sure there is adequate ventilation ( fi g
4
, page 4).
No. in fi g
4
page 4 Explanation
Action
1
Cold intake air
Fit inlet vent to
exterior wall (below
“compressor shelf”)
2
Condenser & Compressor
(“compressor shelf”) – produce
heat
–
3
Hot waste air – external vent
Fit oulet vent to
exterior wall (above
“compressor shelf”)
4
Hot waste air – internal vent
–
6.4 Connecting the refrigerator
Connecting to a battery
The refrigerator can be operated with a 12 V to 24 V DC voltage supply.
To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if
this is possible. For this reason avoid additional switches, plugs or
power strips.
³
Determine the required cross section of the cable in relation to the cable length
according to
3
page 4.
Key for
3
page 4
Co-ordinate axis
Meaning
Unit
I
Cable length
mm
ø
Cable cross-section
mm
2