EN
MDC065(K), MDC090(K)
Troubleshooting
37
Compressor is not running (connected to AC supply)
Poor cooling, interior temperature increases
Start attempt with
U
KL
≤
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low
Replace the battery
Cable cross section too small
Replace the cable
Start attempt with
U
KL
≥
U
ON
Ambient temperature too high
–
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
U
KL
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
Fault
Possible cause
Remedy
No voltage
Interruption in the supply cable
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is present but
the compressor doesn't
run
Ambient temperature too high
–
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
Fault
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Fault
Possible cause
Remedy