In “HIGH” mode, the battery monitor responds faster than at the
levels “LOW” and “MED” (see the following table).
The battery monitor mode can be selected as follows:
➤
Switch on the cooler.
➤
Press the “SET” button (fig.
3
4, page 9) three times.
➤
Use the “UP +” (fig.
3
7, page 9) or “DOWN -” (fig.
3
6,
page 9) buttons to select the battery monitor mode.
➤
Digital display will be as follows:
Lo (LOW),
Π
d (MED), Hi (HIGH)
✓
The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the
current temperature.
I
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
6.5
Using the cooler
A
NOTICE! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the
heat that generated during operation can dissipate. Ensure that
the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the
air can circulate.
➤
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the
heated air can dissipate.
Battery monitor mode
LOW
MED
HIGH
Switch-off voltage at 12 V
10.1 V
11.4 V
11.8 V
Restartvoltage at 12 V
11.1 V
12.2 V
12.6 V
Switch-off voltage at 24 V
21.5 V
24.1 V
24.6 V
Restart voltage at 24 V
23.0 V
25.3 V
26.2 V