EN
Safety
AirConServiceCenter
64
Do not operate the AirConServiceCenter in areas where there is a risk of
explosions (for example battery charging rooms or spraying booths).
Always use the main switch of the AirConServiceCenter to switch the
station on and off. Do not leave the device unattended when it is switched
on.
Before you shut down the AirConServiceCenter, make sure that the
selected programme has ended and that all valves are shut. Otherwise
refrigerant can leak.
Do not pump compressed air into the refrigerant lines of the
AirConServiceCenter or the vehicle air conditioning system. A mixture of
compressed air and refrigerant can be flammable or explosive.
2.2
Warnings on the AirConServiceCenter
Warning!
Observe the operating manual!
Only connect the device to a 230 V/50 Hz AC socket!
Protect the device against rain!
Wear gloves when handling refrigerants!
Wear goggles when handling refrigerants!
2.3
Safety devices
Pressure monitor: switches the compressor off if the normal operating
pressure is exceeded.
Pressure relief valves: additional safety mechanism to protect lines or
vessels from bursting if the pressure continues to rise despite the
safety pressure monitor.