Troubleshooting
Troubleshooting 8.1
77
[en-US] | 09/2022 | 5100061327 | RTLx-SC3 | Operator’s Manual
Problem /
Symptom
Reason
Remedy
No vibration
Machine in high speed travel mode
Reduce machine speed, then press vibration
switch.
Faulty vibration switch or poor connection in-
side transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on vibration valve
Repair or replace.
Damaged exciter assembly
Repair or replace.
Damaged exciter motor coupling
Repair or replace.
Damaged exciter motor
Repair or replace.
Damaged exciter pump
Repair or replace.
Machine out of infrared signal range
Move transmitter closer to machine.
Operator too close to machine
Move away from machine.
Communication fault
See topic
Communication Faults
No travel, or
travel only in
one direction
Faulty forward/reverse switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on travel valve
Repair or replace.
Damaged drive gearcase assembly
Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged drive motor
Repair or replace.
Damaged drive pump
Repair or replace.
Machine out of infrared signal range
Move transmitter closer to machine.
Operator too close to machine
Move away from machine.
Communication fault
See topic
Communication Faults
No high speed
travel
Faulty forward/reverse switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on manifold
Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged exciter pump
Repair or replace.
Vibration is turned on
Turn off vibration.
Machine out of infrared signal range
Move transmitter closer to machine.
Operator too close to machine
Move away from machine.
Communication fault
See topic
Communication Faults
No steering
Faulty left/right joystick switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on steering valve
Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged steering cylinder
Repair or replace.
Locking bar engaged
Disengage locking bar.
Machine out of infrared signal range
Move transmitter closer to machine.
Operator too close to machine
See topic
Communication Faults
8
Содержание RTLx-SC3
Страница 6: ...This page is intentionally left blank...
Страница 89: ...Index 89 en US 09 2022 5100061327 RTLx SC3 Operator s Manual...
Страница 92: ...Cette page est laiss intentionnellement vierge...
Страница 183: ...Index 183 fr 09 2022 5100061327 RTLx SC3 Notice d utilisation...
Страница 184: ......
Страница 185: ......