Technical data
35
11.6
Extension cable
Please refer to the following table for the required cross-section area of cable for
a designated extension.
Note:
Refer to the nameplate or the chapter
Technical data
(via the item
number) for the type designation and voltage rating of your machine.
WARNING
Electrical voltage.
Danger of electrocution!
f
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I).
Machine
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
IREN 38
42
< 29
2.5
< 45
4
48
< 37
2.5
< 58
4
115
< 109
1.5
< 150
2.5
250
< 150
1.5
IREN 40
48
< 37
2.5
< 58
4.0
IREN 45
42
< 20
2.5
< 31
4
< 46
6
48
< 26
2.5
< 41
4
115
< 85
1.5
< 139
2.5
250
< 150
1.5