26
Troubleshooting
IREN
9
Troubleshooting
Potential faults, their causes and remedies can be found in the following table.
Notify your WACKER contact in case of malfunctions you cannot or may not remedy yourself.
Malfunction
Cause
Remedy
Vibrator head does not vibrate.
No line voltage.
- Connect the plug to the in-
verter.
- Check power cable for dam-
age, replace if defective.
Vibrator head has switched off
due to excess temperature.
Deactivate the machine and al-
low the vibrator head to cool
down.
- ON/OFF switch defective.
- Inverter defective.
- Mechanical defect in the vi-
brator head.
Have the machine repaired.
Noticeable sound, vibrator head
runs with reduced power.
One of the thermal overload
protections has switched off
(two phase operation).
Have the machine repaired.
Содержание IREN 38
Страница 1: ...Internal vibrator IREN 38 40 45 57 65 0203044en 005 02 2008 Operator s manual...
Страница 2: ......
Страница 40: ...40 Technical data IREN...
Страница 42: ......
Страница 45: ......
Страница 46: ......