background image

                          

  

            

      

DANGER

CARBON MONOXIDE

Using a generator indoors CAN KILL YOU IN MINUTES.

Generator exhaust contains carbon monoxide (CO). This is a poison you cannot see or 
smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot 
smell the exhaust, you could be breathing CO.

NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed 
areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or 
opening windows and doors does NOT supply enough fresh air.

ONLY use a generator outside and far away from windows, doors, and vents. These 
openings can pull in generator exhaust.

Even when you use a generator correctly, CO may leak into the home. ALWAYS use a 
battery-powered or battery-backup CO alarm in the home.

If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh 
air RIGHT AWAY. See a doctor. You could have carbon monoxide poison.

Содержание GS 5.6A

Страница 1: ...www wackergroup com Generator G 5 6A GS 5 6A OPERATOR S MANUAL 0154587en 004 0706 0 1 5 4 5 8 7 E N...

Страница 2: ...enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outside and far away from wi...

Страница 3: ...2 Engine 13 4 Operation 14 4 1 Determining Power Requirements 14 4 2 Outdoor Installation 15 4 3 Indoor Installation 15 4 4 Recommended Battery GS 5 6A only 15 4 5 Wheel Kit 16 4 6 Generator Derating...

Страница 4: ...ntenance Schedule 27 5 3 Engine Oil 28 5 4 Air Cleaner 29 5 5 Spark Plug 30 5 6 Cleaning the Sediment Cup 31 5 7 Carburetor Adjustment 31 5 8 Auto Idle Speed 32 5 9 Engine Speed 33 5 10 Storage 34 5 1...

Страница 5: ...erviced Follow operating instructions carefully If you have questions about operating or servicing this equipment please contact Wacker Corporation The information contained in this manual was based o...

Страница 6: ...on which if not avoided could result in minor or moderate injury CAUTION Used without the safety alert symbol CAUTION indicates a potentially hazardous situation which if not avoided may result in pro...

Страница 7: ...tions contained in both this manual and the engine manual and familiarize yourself with the location and proper use of all controls Inexperienced operators should receive instruction from someone fami...

Страница 8: ...ns in the engine owner s manual and the safety guidelines below Failure to follow the warnings and safety guidelines could result in severe injury or death 2 3 1 DO NOT run the machine indoors or in a...

Страница 9: ...move the machine and allow the machine to dry before servicing 2 4 5 DO NOT service the machine if your clothing or skin is wet 2 4 6 DO NOT allow untrained personnel to service this equipment Only tr...

Страница 10: ...ELECTRICAL CURRENT FROM THE GENERATOR TO BACKFEED INTO UTILITY LINES THIS MAY RESULT IN ELECTROCUTION OF UTILITY WORKERS FIRE OR EXPLOSION CONNECTIONS TO A BUILDING S ELECTRICAL SYSTEM MUST BE MADE BY...

Страница 11: ...ide operate only in well ventilated area Read the Operator s Manual No sparks flames or burning objects near the machine Shut off the engine before refu eling WARNING Hot surface CAUTION Read and unde...

Страница 12: ...NK posi tion Label Meaning IMPROPER CONNECTION OF GENERATOR TO A BUILDING S ELECTRICAL SYSTEM CAN ALLOW ELECTRICAL CURRENT FROM THE GENERATOR TO BACKFEED INTO UTILITY LINES THIS MAY RESULT IN ELECTROC...

Страница 13: ...it Please record the infor mation found on this plate so it will be available should the nameplate become lost or dam aged When ordering parts or requesting ser vice information you will always be ask...

Страница 14: ...50 Type Dual voltage single phase Auto voltage regulator system AC Voltages Available volts phase 120 240 1 Frequency Hz 60 Power Factor 1 0 AC receptacles 120V GFI duplex 120V GFI duplex 120V twist l...

Страница 15: ...0 031 Engine Speed full load rpm 3600 100 Engine Speed no load rpm 3700 100 Auto Idle Speed rpm 2200 50 Air Cleaner type Dry type with oil wetted foam pre cleaner Battery type V capacity Size in N A Y...

Страница 16: ...tool or appliance with questions regarding its power requirements CAUTION If a tool or appliance does not reach full speed within a few seconds when switched on turn it off immediately to avoid damage...

Страница 17: ...t fumes make sure the exhaust piping is large enough to prevent excessive back pressure to the engine Back pressure reduces engine efficiency and may cause the engine to overheat Exhaust gas from the...

Страница 18: ...lock washer d and nuts to U bolts Torque nuts to 8 1 Nm 6 ft lbs 4 5 3 Insert caps e on U bolts 4 5 4 Assemble washers f next to retaining clips g 4 5 5 Attach tires h with washers i next to wheels i...

Страница 19: ...de also affects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000...

Страница 20: ...000544 A ground connection a is located on the generator frame For proper operating safety this ground terminal must be connected to a good ground source This ground connection must comply with Nation...

Страница 21: ...ss Damaged extension cords can cause electrical shock resulting in serious injury or death DO NOT use worn bare or frayed cords Replace damaged cords immediately Use the chart below as a guide for sel...

Страница 22: ...T O 2 4 0 V A C 2 0 A M P C A U T I O N M A I N C O N T R O L S 1 2 0 V A C 2 0 A M P 3 0 A M P 2 0 A M P R E A D A N D U N D E R S T A N D O P E R A T O R S M A N U A L B E F O R E O P E R A T I N G...

Страница 23: ...rected To restore power to receptacles push the RESET button in If the RESET button pops out during operation stop the generator and check generator and equipment for defects 4 11 Twist Lock Receptacl...

Страница 24: ...dle switch to AUTO The AUTO setting is recommended while the generator is running to minimize fuel consumption To avoid extended engine warm up periods keep switch set to OFF when starting the engine...

Страница 25: ...wever only half the rated power 23 amps is available at the 120V duplex receptacles and the other half at the 120V twist lock receptacle Full power is available at the 240V twist lock receptacle CAUTI...

Страница 26: ...oil level in engine fuel level condition of air cleaner tightness of external fasteners condition of fuel lines Note The engine is equipped with an oil alert system If the oil level in the engine dro...

Страница 27: ...e starts Release the switch after the engine starts CAUTION DO NOT run the starter motor more than 5 seconds at a time or starter motor damage may occur If the engine fails to start release the switch...

Страница 28: ...Turn the engine switch to OFF b2 4 18 4 Close the fuel valve d2 Note To stop the engine quickly in an emergency turn or press the engine switch to OFF b2 4 19 Operating Heavy Loads Limit operations re...

Страница 29: ...ing After first 20 hrs Every 50 hrs Every 100 hrs Every 300 hrs Check the fuel level Check the engine oil level Inspect the air filter Replace as needed Check external hardware Clean the air cleaner e...

Страница 30: ...e interests of environmental protection place a plastic sheet and a container under the machine to collect any liquid that drains off Dispose of this liquid in accordance with environmental protection...

Страница 31: ...flash point solvents for cleaning the air cleaner A fire or explosion could result To service 5 4 1 Remove air cleaner cover a Remove both elements and inspect them for holes or tears Replace damaged...

Страница 32: ...ng the engine Do not touch the muffler while it is hot Note Refer to the Technical Data for the recommended spark plug type and the electrode gap setting 5 5 1 Remove the spark plug and inspect it 5 5...

Страница 33: ...2 Set the pilot screw a two turns out See Note 5 7 3 With the engine idling turn the pilot screw a in or out to the setting that produces the highest rpm 5 7 4 After the pilot screw is adjusted turn t...

Страница 34: ...e 5 8 2 Loosen clamping screw b on auto idle magnet bracket 5 8 3 Start engine and set auto idle switch to Auto 5 8 4 Turn magnet pin a in or out to adjust idle speed to 2200 50 rpm Note To avoid exce...

Страница 35: ...governor which automatically adjusts to varying loads on the engine to maintain a constant speed of 3000 rpm There is no throttle control To set the engine to the proper speed Turn the speed adjusting...

Страница 36: ...l into the cylinder Crank the engine a few turns to distribute the oil to the inside of the cylinder walls 5 10 6 Pull the starter rope slowly until resistance is felt and leave the handle in this pos...

Страница 37: ...od condition Spark plug cap is tight Engine oil level is adequate If engine starts but there is no power at receptacles check that Circuit breaker is closed Connector from generator to control panel i...

Страница 38: ...r Winding 10 120 240V 30A Kit 5 Auxiliary Stator Winding 11 Electromagnet 6 Choke W B Extra wire included in kit Terminate at 120V 30A receptacle w c _ g r 0 0 0 5 5 6 G W R W B W B W G W 2 G R G Y R...

Страница 39: ...Engines D Manual Start Engines Ref Description Ref Description 1 Engine Crank Switch 5 Solenoid 1a OFF 6 Starter 1b RUN 7 Charging Coil 1c START 8 Battery 2 Oil Level Switch 9 Ignition Switch 3 Coil...

Страница 40: ...Maintenance G GS 5 6A wc_tx000164gb fm 38 Notes...

Страница 41: ......

Страница 42: ...02 0 Fax 49 0 89 3 54 02 3 90 Wacker Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Asia Pacific Operations Skyline Tower Suite 2303 2...