GPi 3200 / 4300
Operation
wc_tx001239gb.fm
23
Do not disconnect the battery while the machine is running.
Do not attempt to run the machine without a battery.
Do not attempt to jump-start the machine.
In the event that the machine has a discharged battery, either replace the
battery with a fully charged battery or charge the battery using an appropriate
battery charger. See
Technical Data
for the equivalent battery specification.
Dispose of waste batteries in accordance with local environmental regulations.
2.8
Use of Extension Cords
When a long extension cord is used to connect an appliance or tool to the
generator, a voltage loss occurs—the longer the cord, the greater the voltage loss.
This results in less voltage being supplied to the appliance or tool and increases
the amount of current draw or reduces performance. A heavier cord with a larger
wire size will reduce the voltage loss.
Use the chart below as a guide for selecting proper cable size.
Use only extension cords rated for outdoor use and equipped with a third-wire
ground.
NOTICE:
Operating equipment at low voltage can cause it to overheat.
WARNING
Electric shock hazard. Damaged extension cords can cause electrical shock,
resulting in serious injury or death. DO NOT use worn, bare, or frayed cords.
f
Replace damaged cords immediately.
Current
Load in Watts
Maximum Cable Length in Feet
(Amps)
120V
240V
#10
#12
#14
#16
2.5
300
600
1000.
600
375
250
5
600
1200
500
300
200
125
7.5
900
1800
350
200
125
100
10
1200
2400
250
150
100
-
15
1800
3600
150
100
65
-
20
2400
4800
125
75
50
-
Содержание GPi 4300