Starting
4.13.1 Ensure that the generator is properly installed in an outdoor location.
See Sections
Installation
and
Operator Safety while using Internal
Combustion Engines
for installation warnings and safety guidelines.
4.13.2 Disconnect all loads from the generator.
4.13.3 Open the fuel valve
(a1)
.
Note:
If the engine is cold, move the choke lever to the closed position
(b2)
.
If the engine is hot, set the choke to the open position
(b1)
.
4.13.4 Turn the engine switch to “ON”
(c1)
.
4.13.5 Pull the starter rope
(d)
.
Note:
If the oil level in the engine is low, the red LED at the engine
switch will light and the engine will not start. If this happens, check the
oil level and add oil as needed.
4.13.6 Open the choke as the engine warms
(b1)
.
4.13.7 Allow the engine to warm up a few minutes before attaching loads.
4.14
Stopping
4.14.1 Turn off and disconnect all tools and appliances attached to the
generator.
4.14.2 Turn the engine switch to “OFF”
(c2)
.
4.14.3 Close the fuel valve
(a2)
.
Note:
To stop the engine quickly in an emergency, turn the engine
switch to “OFF”
(c2)
.