G 3.7A;G/GS 5.6A;GS 8.5V;GS 9.7V
Portable Generator Repair
wc_tx000208gb.fm
62
6.18 Receptacle Panel Wiring
Remove receptacle panel from control box and inspect the wiring for
worn or loose wires. Make sure all wire connections are secure and
tight at the screws. DO NOT allow wires to be pinched, kinked or
damaged in any way. Inspect for tight connections at circuit breakers,
capacitors, switches and receptacles. Replace any broken or
damaged parts.
6.19 Loss of Residual Magnetism in Rotor
See Graphic: wc_gr000946
General
If the rotor has been removed, the generator stored for a considerable
time, or the rotor (field) connections reversed during service, the
residual magnetism may have been destroyed. Loss of magnetism will
prevent the generator from building voltage.
To check residual voltage, run the generator at normal no-load speed
and measure the voltage at 120 VAC receptacles. This voltage should
be at least 1.5 volts. If the voltage is less than 1.5 volts, the residual
magnetism must be restored by “flashing” with a 12 volt battery.
Restoring Residual Magnetism to the Brush Type Generators
Disconnect wires F1 and F2 from the AVR (a). Run the generator at its
normal speed and apply 12 volts from a battery to the wires F1 and F2
for approximately 3 seconds. Ensure the positive battery lead is
applied to the red wire F1. The output voltage of the generator, with the
12 volt supply connected, should be approximately normal voltage.
Stop the generator and reconnect leads F1 – F2.
CAUTION: Ensure the battery leads are connected to the wires F1 and
F2 with the correct polarity, and that the wires are isolated from each
other and ground. Loss of residual magnetism will result if wires touch
ground, each other, or wrong polarity.
Содержание G2.5A
Страница 2: ......
Страница 4: ...Foreword Portable Generator Repair wc_tx000224gb fm ii...
Страница 8: ...Table of Contents Portable Generator Repair wc_bo0112013004gbTOC fm 4...
Страница 46: ...G 2 5A Portable Generator Repair wc_tx000207gb fm 42...
Страница 67: ...Portable Generator Repair G 3 7A G GS 5 6A GS 8 5V GS 9 7V wc_tx000208gb fm 63...
Страница 76: ...G 3 7A G GS 5 6A GS 8 5V GS 9 7V Portable Generator Repair wc_tx000208gb fm 72...
Страница 85: ...Portable Generator Repair G 3 7A G GS 5 6A GS 8 5V GS 9 7V wc_tx000208gb fm 81...
Страница 90: ...G 3 7A G GS 5 6A GS 8 5V GS 9 7V Portable Generator Repair wc_tx000208gb fm 86...
Страница 95: ......